www.dadehpardazan.ir 88594014-15
10.2 List of Parameters
10-27
10
Ap
pend
ix
Pn50D
2
Input Signal Selection 4
0000 to FFFF
8888
After restart
Setup
Pn50E
2
Output Signal Selection 1
0000 to 3333
3211
After restart
Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
/ZCLAMP Signal Mapping (Zero clamp when ON (closed))
Reference
Section
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/INHIBIT Signal Mapping (Reference pulse inhibit when ON (closed))
Reference
Section
0 to F
Same as /ZCLAMP Signal Mapping.
/G-SEL1 Signal Mapping (Gain change when ON (closed))
Reference
Section
0 to F
Same as /ZCLAMP Signal Mapping.
/P-DET Signal Mapping (Polarity detection starts when ON (closed))
Reference
Section
0 to F
Same as /ZCLAMP
4th 3rd 2nd 1st
digit digit digit digit
n.
Positioning Completion Signal Mapping (/COIN)
Reference
Section
0
Disabled (the above signal is not used.)
1
Outputs the signal from CN1-25, -26 output terminal.
2
Outputs the signal from CN1-27, -28 output terminal.
3
Outputs the signal from CN1-29, -30 output terminal.
Speed Coincidence Detection Signal Mapping (/V-CMP)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
Servomotor Movement Detection Signal Mapping (/TGON)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
Servo Ready Signal Mapping (/S-RDY)
Reference
Section
0 to 3
Same as /COIN Signal Mapping.
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...