Pn530
2
Program JOG Operation
Related Switch
0000 to 0005
0000
Immediately
Setup
Pn531
4
Program JOG Movement Dis-
tance
1 to
1073741824
1
reference
unit
32768
Immediately
Setup
Pn534
2
Program JOG Acceleration/
Deceleration Time
2 to 10000
1 ms
100
Immediately
Setup
Pn535
2
Program JOG Waiting Time
0 to 10000
1 ms
100
Immediately
Setup
Pn536
2
Number of Times of Program
JOG Movement
0 to 1000
1 time
1
Immediately
Setup
Pn550
2
Analog Monitor 1 Offset
Voltage
-10000 to
10000
0.1 V
0
Immediately
Setup
Pn551
2
Analog Monitor 2 Offset
Voltage
-10000 to
10000
0.1 V
0
Immediately
Setup
Pn552
2
Analog Monitor Magnification
(
1)
-10000 to
10000
0.01
100
Immediately
Setup
Pn553
2
Analog Monitor Magnification
(
2)
-10000 to
10000
0.01
100
Immediately
Setup
Pn560
2
Remained Vibration Detection
Width
1 to 3000
0.1%
400
Immediately
Setup
Pn561
2
Overshoot Detection Level
0 to 100
1%
100
Immediately
Setup
Pn580
2
Zero Clamp Level
0 to 10000
1 mm/s
10
Immediately
Setup
Pn581
2
Zero Speed Level
1 to 10000
1 mm/s
20
Immediately
Setup
Pn582
2
Speed Coincidence Signal
Output Width
0 to 100
1 mm/s
10
Immediately
Setup
Pn583
2
Brake Reference Output Speed
Level
0 to 10000
1 mm/s
10
Immediately
Setup
Pn584
2
Speed Limit Level at Servo ON
0 to 10000
1 mm/s
10000
Immediately
Setup
Pn585
2
Program JOG Movement
Speed
1 to 10000
1 mm/s
50
Immediately
Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Program JOG Operation Switch
0
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
1
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
2
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
3
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
4
(Waiting time Pn535
→
Forward movement Pn531
→
Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
5
(Waiting time Pn535
→
Reverse movement Pn531
→
Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...