www.dadehpardazan.ir 88594014-15
10 Appendix
10.1.1 Connection to MP2200/MP2300 Motion Module SVA-01
10-2
10.1
Connection to Host Controller
The following figures show the connection examples to host controllers.
10.1.1
Connection to MP2200/MP2300 Motion Module SVA-01
Note 1. Connection cables (model: JEPMC-W2040-
) to connect the SERVOPACK to the MP2200/MP2300 are pre-
pared by Yaskawa. For details, refer to
Machine Controller MP2200/2300 Motion Module User’s Manual
(No.:
SIEP C880700 16).
2. Only signals related to the SGDV SERVOPACK and MP2200/MP2300 Motion Module SVA-01 are shown in the
diagram.
3. The main circuit power supply is a three-phase 200 VAC SERVOPACK input in the example.
4. Incorrect signal connections will cause damage to the machine controller and SERVOPACK. Wire all connec-
tions carefully.
CN2
W
V
U
M
Enc
Servomotor
Linear scale
Properly treat the end of
shielded wires.
Serial
converter
unit
AO_0 (NREF)
PAL
PCL
AI_0 (VTG)
DO_2 (PCON)
DO_3
+24 V
DI_2 (ZERO/HOME LS)
SG
PA
PC
SG
AO_1 (TREF)
DO_4
DI_3 (P-OT)
DI_0 (SVALM)
SEN (5 V)
㧙
PBL
AI-GND
DO_1 (ALMRST)
+24 V
DI_5 (EXT/DEC)
SG
AI_1 (TMON)
PB
SG
AO-GND
DO_0 (SV ON)
DI_4 (N-OT)
DI_1 (SRDY)
SG
V-REF
PA
/PA
PC
/PC
SG
T-REF
ALM
CN1/CN2
CN1
P-OT
+24 V IN
ALM+
VTG
TMON
AI-GND
TGON+ (/BRK+)
SG
SEN
/S-RDY-
PB
/PB
SG
/ALM RST
/S-ON
N-OT
/S-RDY+
TGON- (/BRK-)
GND
GND
CN5
SGDV
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
2
5
33
34
19
20
6
9
32
41
45
46
42
47
31
10
4
35
36
28
27
1
30
44
40
43
29
21
22
4
3
2
1
L1C
L3
L2
L1
L2C
0V (For 24 V)
0V (For 24 V)
DO_5 (For VS866, SEN)
0 V (For 24 V)
0 V (For 24 V)
/C-SEL
(Control method switching)
ZERO/HOME LS input
P-OT input
N-OT input
EXT/DEC input
Hood FG
Connector shell
Brake interlock output (+)
Brake interlock output (-)
/P-CL (User setting)
/N-CL (User setting)
Analog monitor 1
(force reference monitor)
Analog monitor 1
(force reference monitor)
Analog monitor 2
(speed monitor)
Analog monitor 2
(speed monitor)
SGDV SERVOPACK
MP2200/MP2300 Motion Module SVA-01
manufactured by
Yaskawa Electric Corporation
Black
Black
White
Red
Analog monitor cable
(JZSP-CA01-E)
Control power
supply
Main circuit power
supply
47
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...