www.dadehpardazan.ir 88594014-15
6 Adjustments
6.2.1 Tuning-less Function
6-12
Operate using S.
(3) Automatically Setting the Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set
when the tuning-less function is enabled.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing tuning-
less function.
(4) Tuning-less Level Settings
Two tuning-less levels are available: the rigidity level and load level. Both levels can be set in the Fn200 util-
ity function or in the Pn170 parameter.
Rigidity Level
a) Using the utility function
To change the setting, refer to
6.2.2 Tuning-less Levels Setting (Fn200) Procedure
.
b) Using the parameter
Gain switching
Not available
–
Offline mass calculation *
Not available
Disable the tuning-less function by setting
Pn170.0 to 0 before executing this function.
Mechanical analysis*
Available
While this function is being used, the tuning-
less function cannot be used. After
completion of the analysis, it can be used
again.
(cont’d)
Function
Availability
Remarks
Parameter
Meaning
When Enabled
Classification
Pn460
n.
0
Does not set the 2nd notch filter automatically with
utility function.
Immediately
Tuning
n.
1
[Factory setting]
Set the 2nd notch filter automatically with utility
function.
Digital Operator Display
Meaning
Level 0
Rigidity level 0
Level 1
Rigidity level 1
Level 2
Rigidity level 2
Level 3
Rigidity level 3
Level 4
[Factory setting]
Rigidity level 4
Parameter
Meaning
When Enabled
Classification
Pn170
n.
0
Rigidity level 0 (Level 0)
Immediately
Setup
n.
1
Rigidity level 1 (Level 1)
n.
2
Rigidity level 2 (Level 2)
n.
3
Rigidity level 3 (Level 3)
n.
4
[Factory setting]
Rigidity level 4 (Level 4)
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...