www.dadehpardazan.ir 88594014-15
10 Appendix
10.2.2 Parameters
10-14
Pn00B
2
Application Function Select
Switch B
0000 to 1111
0000
After restart
Setup
Pn00C
2
Application Function Select
Switch C
0000 to 0111
0000
After restart
Setup
Pn00D
2
Application Function Select
Switch D
0000 to 1001
0000
Immediately
Setup
–
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Parameter Display Selection
Reference
Section
0
Setup parameters
1
All parameters
Alarm Gr.2 Stop Method Selection
Reference
Section
0
Stops the motor by setting the speed reference to "0".
1
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Power Supply Method for Three-phase SERVOPACK
Reference
Section
0
Three-phase power supply
1
Single-phase power supply
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Selection of Test without a Motor
0
Disables test without a motor.
1
Enables test without a motor.
Reserved (Do not change.)
Encoder Type for Test without a Motor
0
Incremental linear scale
1
Absolute linear scale
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
Reference
Section
0
Does not detect overtravel warning.
1
Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...