5 Operation
5.5.3 Force Reference Filter
5-54
5.5.3
Force Reference Filter
This smooths the force reference by applying a first order lag filter to the force reference (T-REF) input.
Note: A setting value that is too large, however, will slow down response.
Check the response characteristics when setting this parameter.
5.5.4
Speed Limit in Force Control
This function limits the speed of the servomotor to protect the machine.
A servomotor in force control is controlled to output the specified force, but the motor speed is not controlled.
Therefore, if an excessive reference force is set for the load force on the machinery side, the speed of the ser-
vomotor may increase greatly. If that may occur, use this function to limit the speed.
Note: The actual limit value of motor speed depends on the load conditions of the servomotor.
Refer to the following parameters for speed limit.
(1) Signals Output during Servomotor Speed Limit
The following signal is output when the motor speed reaches the limit speed.
Note: Use parameter Pn50F.1 to allocate the /VLT signal for use. For details, refer to
3.3.2 Output Signal Allocations
.
(2) Speed Limit Setting
Select the speed limit mode with Pn002.1.
Pn415
T-REF Filter Time Constant
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
0.01 ms
0
Immediately
Setup
Speed
Position
Force
With No Speed Limit
With Speed Limit
Motor speed
Time
Maximum speed
Danger of damage due to
critical speed.
Motor speed
Limiting speed
Safe operation with
speed limit.
Time
Type
Signal
Name
Connector
Pin Number
Setting
Meaning
Output
/VLT
Must be allocated
ON (closed)
Servomotor speed limit being applied.
OFF (open)
Servomotor speed limit not being applied.
Parameter
Meaning
When
Enabled
Classification
Pn002
n.
0
[Factory setting]
Uses the value set in Pn480 as the speed limit (internal
speed limit function).
After restart
Setup
n.
1
Uses V-REF (CN1-5, 6) as an external speed limit
input. Applies a speed limit using the input voltage of
V-REF and the setting in Pn300 (external speed limit
function).
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...