www.dadehpardazan.ir 88594014-15
5 Operation
5.4.3 Reference Pulse Input Multiplication Switching Function
5-42
5.4.3
Reference Pulse Input Multiplication Switching Function
The input multiplier for the position reference pulses can be switched between 1 and n (n = 1 to 100) by turn-
ing the Reference Pulse Input Multiplication Switching Input signal (/PSEL) ON and OFF. The Reference
Pulse Input Multiplication Switching Output signal (/PSELA) can be used to confirm that the multiplier has
been switched.
To use this function, set the multiplier in Pn218.
Switch the multiplier of the reference pulse only when the position reference pulse is 0. If the position refer-
ence pulse is not 0 when the multiplier is switched, the servomotor position may shift.
Note: The reference pulse input multiplication switching function is supported by software version 001A or later. The soft-
ware version can be checked with Fn012. For details, refer to
7.14 Software Version Display (Fn012)
.
(1) Related Parameter
(2) Timing Chart for Reference Pulse Input Multiplication Switching
(3) Input Signal Setting
Use the /PSEL signal when switching to the multiplier of the input reference pulse that is set in Pn218.
Note: Use parameter Pn515.1 to allocate the /PSEL signal for use. For details, refer to
3.3.1 Input Signal Allocations
s
to
Input Terminals
.
CAUTION
• Unexpected operation may occur if a position reference pulse is input before the multiplier changes.
Always use the /PSELA signal to confirm that the multiplier has been switched before inputting a position
reference pulse.
• If changing the setting of Pn218, be sure that no problems will occur upon operation before configuring the
servomotor and other parts of the machine system.
Pn218
Reference Pulse Input Multiplication
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 100
1 time
1
Immediately
Setup
Position
×
1
×
n
(n = Pn218)
×
1
Enabled
Enabled
Disabled
Disabled
SERVOPACK internal status
4 ms or less
4 ms or less
Reference Pulse Input
Multiplication Switching Input signal (/PSEL)
Reference Pulse Input
Multiplication Switching Output signal (/PSELA)
Analog
Type
Signal
Name
Connector
Pin Number
Setting
Meaning
Input
/PSEL
Must be allocated
ON (closed)
Enables the multiplier of the input reference pulse.
OFF (open)
Disables the multiplier of the input reference pulse.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...