4.7 Install the Keypad in a Control Panel or Another Device
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
321
1.
Use the panel cut-out dimensions in
and
to cut an opening in the control panel for the
keypad.
Figure 4.15 Panel Cut-Out Dimensions to Attach Inside Control Panel
Table 4.10 Panel Cut-Out Dimensions mm (in)
W
H
W1
H1
d
64 + 0.5
(2.52 + 0.02)
130
(5.12)
45
(1.77)
105 + 0.5
(4.13 + 0.02)
4.8
(0.12)
2.
Remove the keypad and put the keypad connector in the holder on the front cover.
Note:
Insert the end of the keypad connector that has the tab.
A - Keypad
B - Keypad connector
C - Holder
Figure 4.16 Remove the Keypad
3.
Use the screws included with the mounting bracket, and attach the keypad to the mounting bracket.
Use the screws included with the installation support set to attach it. Tighten the screws to a correct tightening
torque:
• M3 screws: 0.49 N
∙
m to 0.73 N
∙
m (4.34 in
∙
lb to 6.46 in
∙
lb)
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 430: ...5 18 Motor Application Precautions 430 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...