YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
511
7.2
Drive Duty Modes
The drive has two duty modes from which to select for the application: Heavy Duty (HD) and Normal Duty (ND).
Refer to
for information about the differences between HD and ND ratings.
Table 7.1 Drive Duty Modes
Duty Rating
C6-01
Setting
Application
Default Carrier Frequency
Overload Tolerance (
oL2 [Drive
Overload]
)
Heavy Duty Rating
(HD)
0
•
Extruder
•
Conveyor
•
Constant torque or high overload capacity
2 kHz
150% of the rated output current for
60 seconds The permitted frequency
of overload is one time each 10
minutes.
Normal Duty Rating
(ND)
1
•
Fan
•
Pump
•
Blower
•
Variable speed control
2 kHz Swing-PWM
110% of the rated output current for
60 seconds The permitted frequency
of overload is one time each 10
minutes.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 430: ...5 18 Motor Application Precautions 430 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...