2.2 Types of Faults, Minor Faults, Alarms, and Errors
76
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
2.2
Types of Faults, Minor Faults, Alarms, and Errors
If the drive or motor do not operate correctly, check the drive keypad for a code or message.
If problems occur that are not identified in this manual, contact the nearest Yaskawa representative with this
information:
•
Drive model
•
Drive software version
•
Date of purchase
•
Description of the problem (such as failure conditions)
contains descriptions of the different types of faults, minor faults, alarms, and errors that can occur during
drive operation.
Contact Yaskawa if there is damage to the drive. Contact information is on the back cover of the manual.
Table 2.1 Types of Faults, Minor Faults, Alarms, and Errors
Type
Drive Response
Faults
When the drive detects a fault, it will cause these conditions:
•
The keypad shows the fault code and
and ALM/ERR of the LED Status Ring illuminate continuously.
•
The drive shuts off output, and the motor coasts to a stop. Some faults let the user select a motor stopping method.
•
Fault relay output MA-MC will turn ON, and MB-MC will turn OFF.
The drive will not operate until you clear the fault with a Fault Reset and the drive goes back to usual status.
Minor Faults/Alarms
When the drive detects a minor fault or an alarm, it will cause these conditions:
•
The keypad shows the alarm code and
and ALM/ERR on the LED Status Ring flash.
•
The drive will continue to operate the motor. Some alarms let the user select a motor stopping method.
•
If the drive detects a minor fault, the terminal set to
H2-01 to H2-03 = 10 [MFDO Function Select = Alarm]
will switch ON.
If you do not set parameters
H2-01 to H2-03
, the drive will not trigger MFDO terminals when it detects a minor fault.
•
The drive will not output a minor fault signal when it detects an alarm.
It is not necessary to do Fault Reset.
Operation Errors
An error occurs when parameter settings do not agree or a parameter combination is incorrect. The drive will not operate until
you set the parameters correctly.
When the drive detects an operation error, these conditions will result:
•
The keypad shows the error code.
•
Multi-function outputs do not output an alarm signal.
Find the parameters that caused the error and correct the settings.
Auto-Tuning Errors
An error occurs during Auto-Tuning.
When the drive detects a tuning error, it will cause these conditions:
•
The keypad shows the error code.
•
Multi-function outputs do not output an alarm signal.
•
The motor coasts to stop.
Remove the cause of the error and do Auto-Tuning again.
Copy Function Errors
An error occurs when you use the keypad for a backup, restore, or verify operation.
When the drive detects a copy function error, it will cause these conditions:
•
The keypad shows the error code.
•
Multi-function outputs do not output an alarm signal.
Push a key on the keypad to clear the error. Remove the cause of the error and try the backup, restore, or verify operation again.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 430: ...5 18 Motor Application Precautions 430 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...