3.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
275
No.
Name
Range
Unit
Control Method (A1-02 Setting)
OLV/PM
(5)
AOLV/PM
(6)
CLV/PM
(7)
EZOLV
(8)
b3-01
Speed Search at Start
Selection
0 - 1
1
0
0
-
0
b3-02
SpeedSearch
Deactivation Current
0 - 200
1%
-
-
-
-
b3-08
Speed Estimation ACR
P Gain
0.00 - 6.00
0.01
0.30
0.30
-
b3-09
Speed Estimation ACR
I Time
0.0 - 1000.0
0.1 ms
2.0
4.0
-
10.0
b3-14
Bi-directional Speed
Search
0 - 1
1
-
-
-
0
b5-15
PID Sleep Function
Start Level
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
b6-01
Dwell Reference at
Start
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
b6-03
Dwell Reference at Stop 0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
b8-02
Energy Saving Gain
0.0 - 10.0
0.1
-
-
-
-
b8-03
Energy Saving Filter
Time
0.00 - 10.00
0.01 s
-
-
-
-
b8-19
E-Save Search Injection
Freq
10 - 300
1 Hz
-
100
100
20
C1-11
Accel/Decel Time
Switchover Freq
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
C2-01
S-Curve Time @ Start
of Accel
0.00 - 10.00
0.01 s
1.00
0.20
0.20
1.00
C3-01
Slip Compensation Gain 0.0 - 2.5
0.1
-
-
-
0.0
C3-02
Slip Compensation
Delay Time
0 - 10000
1 ms
-
-
-
200
C4-01
Torque Compensation
Gain
0.00 - 2.50
0.01
0.00
-
-
0.00
C4-02
Torque Compensation
Delay Time
0 - 60000
1 ms
100
-
-
200
C5-01
ASR Proportional Gain
1
0.00 - 300.00
0.01
-
10.00
20.00
10.00
C5-02
ASR Integral Time 1
0.000 - 60.000
0.001 s
-
0.500
0.500
0.500
C5-03
ASR Proportional Gain
2
0.00 - 300.00
0.01
-
10.00
20.00
10.00
C5-04
ASR Integral Time 2
0.000 - 60.000
0.001 s
-
0.500
0.500
0.500
C5-06
ASR Delay Time
0.000 - 0.500
0.001 s
-
0.016
0.004
0.004
C5-07
ASR Gain Switchover
Frequency
0.0 - 400.0
0.1
-
0.0%
0.0%
0.0 Hz
C6-02
Carrier Frequency
Selection
1 - F
1
2
2
2
2
d3-01
Jump Frequency 1
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-02
Jump Frequency 2
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-03
Jump Frequency 3
0.0 - 400.0
0.1
0.0 Hz
0.0%
0.0%
0.0 Hz
d3-04
Jump Frequency Width
0.0 - 20.0
0.1
1.0 Hz
1.0%
1.0%
1.0 Hz
d5-02
Torque Reference Delay
Time
0 - 1000
1 ms
-
0
0
-
E1-04
Maximum Output
Frequency
40.0 - 590.0
0.1 Hz
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-05
Maximum Output
Voltage
0.0 - 255.0
0.1 V
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-06
Base Frequency
0.0 - 590.0
0.1 Hz
Determined by E5-01 Determined by E5-01 Determined by E5-01
-
E1-07
Mid Point A Frequency
0.0 - 590.0
0.1 Hz
-
-
-
-
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 430: ...5 18 Motor Application Precautions 430 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...