3.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
277
*6
The maximum value changes when
A1-02
changes:
•
When
A1-02 = 5 [PM Open Loop Vector]
, the maximum value is 590.0 Hz. The maximum value of the setting range changes when
E5-
01 [PM Motor Code Selection]
changes. When
E5-01 = FFFF [PM Motor Code Selection = FFFF]
, the maximum value is 590.0 Hz.
•
When
A1-02 = 6 or 7 [PM Advanced Open Loop Vector or PM Closed Loop Vector]
, the maximum value is 400.0 Hz. The maximum
value of the setting range changes when
E5-01
changes. When
E5-01 = FFFF
, the maximum value is 400.0 Hz.
*7
This is the value for 200 V class drives. Double the value for 400 V class drives.
*8
The default setting changes when
E9-01 [Motor Type Selection]
changes.
•
E9-01 = 0 [Induction (IM)]
: 1
•
E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
: 4
*9
The default setting changes when
E9-01 [Motor Type Selection]
changes.
•
E9-01 = 0 [Induction (IM)]
: 0
•
E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
: 1
*10
The maximum value changes when
A1-02
changes:
•
When
A1-02 = 5 [PM Open Loop Vector]
, the maximum value is 590.0 Hz.
•
When
A1-02 = 6 or 7 [PM Advanced Open Loop Vector or PM Closed Loop Vector]
, the maximum value is 100.0%.
•
When
A1-02 = 8 [EZ Vector Control]
, the maximum value is 120.0 Hz.
*11
The minimum value changes when
A1-02
changes:
•
When
A1-02 = 5 [PM Open Loop Vector]
, the minimum value is -590.0 Hz.
•
When
A1-02 = 6 or 7 [PM Advanced Open Loop Vector or PM Closed Loop Vector]
, the minimum value is -100.0%.
•
When
A1-02 = 8 [EZ Vector Control]
, the minimum value is -120.0 Hz.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 430: ...5 18 Motor Application Precautions 430 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Страница 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...