TT-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
168 of 198
27.7 Series 94 - Preliminary Circuit Analysis
In order to diagnose the ca
u
se of pro
b
lems in this
system it is necessary to determine certain
v
al
u
es. It
is helpf
u
l to ha
v
e a
v
olt/ohm m
u
ltimeter.
Mod
u
lation F
u
nction: If sensed temperat
u
re
(controller display) is less than minim
u
m dial setting
temperat
u
re, perform Step 1
b
elo
w
; other
w
ise
contin
u
e on to Step 2.
Temperat
u
re Sensor F
u
nction: Perform the entire
"Mod
u
lation F
u
nction" analysis, implementing Step 1.
(Step 1 isolates the sensor f
u
nction from the
system).
1. Disconnect the sensor
w
ires to terminals
(amplifier - 8 and 9, amplifier/selector - 1 and
2) and replace
w
ith s
u
pplied test resistor or
w
ith other means to o
b
tain a resistance
v
al
u
e
falling
w
ithin the temperat
u
re range to
b
e
tested, referencing temperat
u
re ta
b
le
b
elo
w
.*
2.
Connect a DC
v
olt meter to terminals 3 and 4,
or at the M/MR
v
al
v
e terminals. Do not discon-
nect existing
w
iring.
3.
Rotate temperat
u
re dial kno
b
to maxim
u
m set-
ting - the DC
v
olts sho
u
ld read at least 17.5 V
DC. Rotate temperat
u
re dial kno
b
to minim
u
m
setting - the DC
v
olts sho
u
ld read no more than
2.0 V DC. DC
v
oltage sho
u
ld grad
u
ally
increase as the dial temperat
u
re setting is
slo
w
ly rotated
u
p to and past the controller's
digital display temperat
u
re.
Table 43: Resistance/Temperature Table
Approximate controller display temperature with 1100 to 1800
ohms resistance across terminals (amplifier - 8 and 9, amplifier/
selector - 1 and 2).
27.7.1 Series 94 - Temperature Calibration
Occasionally the set point that is indicated on the
dial does not match the LED display. This is
u
s
u
ally a
indication that cali
b
ration is req
u
ired. To cali
b
rate the
set-point controls, follo
w
the steps listed
b
elo
w
. The
LED display is to
b
e considered master, d
u
ring these
steps.
27.7.1.1 Calibration of Spray Temperature Selector
NOTE:
Cali
b
ration can not
b
e done if room
temperat
u
re is 90 °F or higher.
1. Place the S
u
mmer/Off/Winter s
w
itch in the
Winter position.
2.
Loosen the setscre
w
that holds the kno
b
to the
shaft of the selector.
3.
Rotate the kno
b
, taking care not to mo
v
e the
shaft, in the direction needed to align the dial
setting to the LED display.
4.
Tighten do
w
n the setscre
w
.
•
Cali
b
ration is no
w
complete.
27.7.1.2 Calibration of Dry Temperature Selector
1. Acti
v
ate the dry cycle.
2.
Place the S
u
mmer/Off/Winter s
w
itch in the
Winter position.
3.
Loosen the setscre
w
that holds the kno
b
to the
shaft of the selector.
4.
Rotate the kno
b
, taking care not to mo
v
e the
shaft, in the direction needed to align the dial
setting to the LED display.
5.
Tighten do
w
n the setscre
w
.
•
Cali
b
ration is no
w
complete.
R (ohms)
T (de
g
rees)
1,100
78 °F (25 °C)
1,200
125 °F (50 °C)
1,300
172 °F (80 °C)
1,400
220 °F (100 °C)
1,500
270 °F (130 °C)
1,600
15 °F (160 °C)
1,700
365 °F (185 °C)
1,800
410 °F (210 °C)
Содержание TT Series
Страница 2: ......
Страница 4: ......
Страница 136: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 130 of 198 FIGURE 114 Regulator RV61 ...
Страница 167: ...SECTION27 TROUBLESHOOTING 161 of 198 ...
Страница 175: ...SECTION27 TROUBLESHOOTING 169 of 198 ...
Страница 176: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 170 of 198 27 7 2 Series 94 Field Service Checklist ...
Страница 177: ...SECTION27 TROUBLESHOOTING 171 of 198 ...
Страница 198: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 192 of 198 ...
Страница 202: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 196 of 198 ...
Страница 203: ...SECTION 28 THE WEATHER RITE TT SERIES WARRANTY 197 of 198 ...
Страница 204: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 198 of 198 ...