SECTION 24: S
TART
-
UP
P
ROCEDURES
123 of 198
Installation Code and Annual Inspections:
All installation and ser
v
ice of WEATHER-RITE
™
eq
u
ipment m
u
st
b
e performed
b
y a contractor
q
u
alified in the installation and ser
v
ice of eq
u
ipment
sold and s
u
pplied
b
y Weather-Rite LLC and conform
to all req
u
irements set forth in the WEATHER-RITE
™
man
u
als and all applica
b
le go
v
ernmental a
u
thorities
pertaining to the installation, ser
v
ice, operation and
la
b
eling of the eq
u
ipment.
To help facilitate optim
u
m performance and safety,
Weather-Rite LLC recommends that a q
u
alified
contractor cond
u
ct, at a minim
u
m, ann
u
al
inspections of yo
u
r WEATHER-RITE
™
eq
u
ipment
and perform ser
v
ice
w
here necessary,
u
sing only
replacement parts sold and s
u
pplied
b
y Weather-Rite
LLC.
Check installation site to ens
u
re all codes and
engineering specifications are correct. This section of
the man
u
al is intended to
b
e
u
sed as an instr
u
ctional
g
u
ide to the commissioning of the direct fired air
handler. Fill o
u
t the attached start
u
p sheet (located
at the
b
ack of the man
u
al) as each step of the
proced
u
re is performed. This proced
u
re sho
u
ld
b
e
completed
b
y the commissioning contractor and
ret
u
rned to Weather-Rite LLC. If the doc
u
ment is not
ret
u
rned, the man
u
fact
u
ring date
w
ill
b
e
u
sed as the
w
arranty start date.
24.1 Installation of Recirculatin
g
Air Handler
E
v
ery direct-fired air handler
w
hich recirc
u
lates room
air (AM style) m
u
st
u
tilize either a control system
w
hich limits temperat
u
re rise in proportion to the
amo
u
nt of o
u
tdoor air, or a room car
b
on dioxide
sensor, installed per the man
u
fact
u
rer's
recommendations. The normally closed contacts of
this sensor m
u
st
b
e
w
ired in as per the air handler's
w
iring diagram, maintaining the room concentration
of CO2
b
elo
w
5,000 ppm.
24.2 Mechanical
Refer to appliance rating plate for minim
u
m o
u
tside
air req
u
irements d
u
ring recirc
u
lation operation.
Before installation, check that the local distri
bu
tion
condition, nat
u
re of gas and press
u
re, and the
c
u
rrent state of adj
u
stment of the appliance are
compati
b
le.
If filters are not installed (
v
ia inlet hood or filter
section), an air strainer m
u
st
b
e installed on the inlet
of the air handler
w
ith openings less than or eq
u
al to
5/8" (16 mm) in diameter.
Air inlets m
u
st
b
e installed
w
ith the lo
w
est edge 16"
(406.4 mm) a
b
o
v
e any s
u
rface. This applies to roof
c
u
r
b
s,
u
pright stands and s
u
spended air handlers.
24.2.1 Sheave Ali
g
nment
Shea
v
es are factory aligned. On all air handlers,
check shea
v
e alignment as follo
w
s:
1. A string to the
v
ertical s
u
rface next to the
b
lo
w
er shaft
b
earing. (
See Page 123, Figure
107
)
2.
Wrap the string aro
u
nd the
b
lo
w
er shea
v
e and
across
b
oth shea
v
e s
u
rfaces as sho
w
n.
3.
Adj
u
st
u
ntil all fo
u
r contact points to
u
ch the
shea
v
e s
u
rfaces. "IN" or "OUT" adj
u
stment of
the motor shea
v
e and/or motor adj
u
stment
may
b
e req
u
ired.
4.
P
u
ll the string a
w
ay from the motor shea
v
e and
then mo
v
e it slo
w
ly
b
ack to
w
ards the shea
v
e,
making s
u
re the string remains straight
w
hile
to
u
ching all contact points.
5.
Remo
v
e string
b
efore t
u
rning air handler on.
NOTE
: Allo
w
ances m
u
st
b
e made for motor shea
v
es
w
hich are
w
ider than the
b
lo
w
er shea
v
es.
FIGURE 107: Sheave Ali
g
nment
24.2.2 Belt Tension
• Belt tension sho
u
ld
b
e checked
w
ith a
b
elt-tension
ga
u
ge
w
hen one is a
v
aila
b
le. Follo
w
the
b
elt
tension ga
u
ge instr
u
ctions.
• When a tension ga
u
ge is not a
v
aila
b
le, meas
u
re
the
b
elt span of the
b
elts. (
See Page 124, Figure
108
.)
• Allo
w
for 1/64" (.04 cm) of deflection for each inch
of center distance length for the charted po
u
nds
of force. Check the ta
b
le
b
elo
w
for proper
deflection force.
• EXAMPLE: A 40" (101.6 cm) shaft center
distance
w
o
u
ld dictate 40"/64" or 5/8" (1.59
cm) of deflection. With a standard B-type
Correct Alignment
Incorrect Alignment
Содержание TT Series
Страница 2: ......
Страница 4: ......
Страница 136: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 130 of 198 FIGURE 114 Regulator RV61 ...
Страница 167: ...SECTION27 TROUBLESHOOTING 161 of 198 ...
Страница 175: ...SECTION27 TROUBLESHOOTING 169 of 198 ...
Страница 176: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 170 of 198 27 7 2 Series 94 Field Service Checklist ...
Страница 177: ...SECTION27 TROUBLESHOOTING 171 of 198 ...
Страница 198: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 192 of 198 ...
Страница 202: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 196 of 198 ...
Страница 203: ...SECTION 28 THE WEATHER RITE TT SERIES WARRANTY 197 of 198 ...
Страница 204: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 198 of 198 ...