SECTION 27: T
ROUBLESHOOTING
175 of 198
27.
8
.1.3 Menus
Loopin
g
Mode
(TM02
applications
only)
The looping mode feat
u
re is
u
sed to select the controllers defa
u
lt position on start
u
p and
after the last process of a program is completed.
NOTE: Glo
b
al Setting for MP2+ system.
NOTE: For MP2+ system, On "Po
w
er
u
p" the controller defa
u
lts to the last program in
u
se
prior to remo
v
al of po
w
er. After last man
u
al process of a program or after last timed pro-
cess of a program expires, the controller defa
u
lts to the first process of the same program.
F/C Mode
This feat
u
re sets the control to operate in either the Fahrenheit (F) or Celsi
u
s (C) mode.
NOTE: Changing
b
et
w
een Fahrenheit and Celsi
u
s
w
ill reset the control to factory defa
u
lt
settings.
NOTE: Glo
b
al Setting for MP2+ system.
Software
Version
Displays the
v
ersion of soft
w
are
u
tilized
b
y the controller.
Pro
g
ram
Indication
Output
See MP2 or MP2+ Select Information
Selectin
g
"READY"
Power up:
"READY" is displayed. Req
u
ires a momentary s
w
itch clos
u
re
to mo
v
e the controller to the first process.
After last, manual process of a pro
g
ram:
After momentary s
w
itch clos
u
re to mo
v
e o
u
t of the last process,
controller defa
u
lts to the "READY" position.
After last, timed process of a pro
g
ram expires:
Controller defa
u
lts to the "READY" position.
Selectin
g
"First Process"
Power up:
Controller
b
egins operating in the First Process of the program.
After last, manual process of a pro
g
ram:
After momentary s
w
itch clos
u
re to mo
v
e o
u
t of the last process,
controller defa
u
lts to the First Process.
After last, timed process of a pro
g
ram expires:
Controller defa
u
lts to the First Process.
Initial
Men
u
(f
or MP2+
s
y
st
em onl
y)
Pro
g
rams
Program Set (1-8), Process Men
u
, Operation Men
u
,
Diagnostic Men
u
Global Settin
g
s
Operation Men
u
, Diagnostic Men
u
P
roces
s Me
n
u
Process Temperatures
Temp Set Point Process #(1 - 8)
Off, 60 °F (15 °C) to 240 °F (115 °C)
Process Time
NOTE: TM02 req
u
ired
Time Process #(1 - 8) ??Ho
u
rs, Min
u
tes, Seconds
Man
u
al, 00:00:01 to 23:59:59
Содержание TT Series
Страница 2: ......
Страница 4: ......
Страница 136: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 130 of 198 FIGURE 114 Regulator RV61 ...
Страница 167: ...SECTION27 TROUBLESHOOTING 161 of 198 ...
Страница 175: ...SECTION27 TROUBLESHOOTING 169 of 198 ...
Страница 176: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 170 of 198 27 7 2 Series 94 Field Service Checklist ...
Страница 177: ...SECTION27 TROUBLESHOOTING 171 of 198 ...
Страница 198: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 192 of 198 ...
Страница 202: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 196 of 198 ...
Страница 203: ...SECTION 28 THE WEATHER RITE TT SERIES WARRANTY 197 of 198 ...
Страница 204: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 198 of 198 ...