SECTION 1
8
: G
AS
P
IPING
81 of 198
FIGURE 67: FM Manifold above 3000 MBH 2 ½" to 3" NPT
FIGURE 6
8
: XL Manifold Less than 1000 MBH - 1" NPT
Honey
well
FLUID POWER GAS
VAL
VE
FLUID POWER GAS
VAL
VE
Honey
well
M
AXITROL
Selec
tra
PILOT GAS REGULATOR
CONTROLS THE AMOUNT OF
GAS FLOW TO THE
BURNER'S PILOT TUBE.
PILOT SOLENOID VALVE.
ALLOWS GAS TO FLOW TO
THE BURNER PILOT.
METERING VALVE.
CONTROLS THE FLOW OF
GAS TO THE MAIN BURNER
& TO SET THE LOW FIRE
ON THE BURNER.
BLOCK GAS MOTORIZED ACTUATOR
SECONDARY BACK-UP.
OPENS AND CLOSES VALVE.
MAIN GAS MOTORIZED ACTUATOR.
OPENS & CLOSES VALVE ALLOWING
GAS TO FLOW TO THE BURNER.
MOTORIZED BLOCK
VALVE BODY.
SECONDARY BACK-UP
VALVE TO PREVENT GAS
FROM REACHING THE
BURNER DURING
SHUTDOWN.
PILOT SHUT-OFF COCK
MANUAL SHUT OFF THAT ISOLATES
THE PILOT GAS ASSEMBLY FROM
THE MAIN GAS SUPPLY.
MAIN GAS VALVE BODY
OPENS & CLOSES ALLOWING
GAS TO FLOW TO THE BURNER.
SHUT-OFF COCK.
MANUAL SHUT OFF THAT ISOLATES
THE GAS TRAIN ASSEMBLY FROM
THE BURNER.
LOW GAS PRESS. SWITCH
PROTECTS AGAINST
INSUFFICIENT GAS
PRESSURE.
HIGH GAS PRESS. SWITCH
PROTECTS AGAINST EXCESSIVE GAS
PRESSURE
PILOT GAS REGULATOR
CONTROLS THE AMOUNT OF
GAS FLOW TO THE
BURNER'S PILOT TUBE.
POSITION INDICATING BLOCK
GAS SOLENOID VALVE.
SECONDARY BACK-UP VALVE TO
PREVENT GAS FROM REACHING
BURNER DURING SHUTDOWN.
MAIN GAS PRESSURE REGULATOR
CONTROL THE FLOW OF GAS TO
THE MAIN BURNER & TO SET
THE HIGH FIRE ON THE BURNER
PILOT SHUT-OFF COCK
MANUAL SHUT OFF THAT ISOLATES
THE PILOT GAS ASSEMBLY FROM
THE MAIN GAS SUPPLY.
POSITION INDICATING MAIN
GAS SOLENOID VALVE.
OPENS & CLOSES ALLOWING
GAS TO FLOW TO THE BURNER.
PILOT SOLENOID VALVE.
ALLOWS GAS TO FLOW TO
THE BURNER PILOT.
METERING VALVE.
CONTROLS THE FLOW OF
GAS TO THE MAIN BURNER
& TO SET THE LOW FIRE
ON THE BURNER.
HIGH GAS PRESS. SWITCH
PROTECTS AGAINST EXCESSIVE GAS
PRESSURE
LOW GAS PRESS. SWITCH
PROTECTS AGAINST
INSUFFICIENT GAS
PRESSURE.
Содержание TT Series
Страница 2: ......
Страница 4: ......
Страница 136: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 130 of 198 FIGURE 114 Regulator RV61 ...
Страница 167: ...SECTION27 TROUBLESHOOTING 161 of 198 ...
Страница 175: ...SECTION27 TROUBLESHOOTING 169 of 198 ...
Страница 176: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 170 of 198 27 7 2 Series 94 Field Service Checklist ...
Страница 177: ...SECTION27 TROUBLESHOOTING 171 of 198 ...
Страница 198: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 192 of 198 ...
Страница 202: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 196 of 198 ...
Страница 203: ...SECTION 28 THE WEATHER RITE TT SERIES WARRANTY 197 of 198 ...
Страница 204: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 198 of 198 ...