20.1.1 Make-Up Air (MUA) Style
The MUA style air handler has a constant speed
b
lo
w
er that is designed to deli
v
er a constant
v
ol
u
me
of air to the heated space. This style air handler
s
u
pplies 100% o
u
tside air to the heated space and is
not capa
b
le of s
u
pplying ret
u
rn air.
20.1.2 Volumatic Recirculatin
g
The VR style air handler has a constant speed
b
lo
w
er that is designed to deli
v
er a constant
v
ol
u
me
of air to the heated space. The standard control is
man
u
al,
w
ith options a
v
aila
b
le to allo
w
for a
bu
ilding
press
u
re sensor is
u
sed to detect and control the
differential press
u
re
b
et
w
een the o
u
tside and the
heated space. The total
v
ol
u
me of air deli
v
ered
b
y
the air handler may at times consist of 0% to 80%
ret
u
rn air.
20.1.3 Volumatic with VFD
The Vol
u
matic
w
ith VFD style air handler
u
ses
mod
u
lating discharge dampers to control o
u
tside air
deli
v
ered to the space (this style air handler does not
ret
u
rn any air from the
bu
ilding). Proper air
v
elocity /
press
u
re drop o
v
er the
bu
rner is maintained
b
y
a
u
tomatic mod
u
lating profile dampers. This style is
a
v
aila
b
le in t
w
o
v
ersions - T
w
o Position Vol
u
matic
and F
u
ll Vol
u
matic. The T
w
o Position Vol
u
matic
deli
v
ers 100% of the o
u
tside air and to a pre-selected
second
v
al
u
e of airflo
w
(operator determined) do
w
n
to 25% of the f
u
ll CFM rating of the air handler. F
u
ll
Vol
u
matic allo
w
s f
u
ll control of air flo
w
from 100%
do
w
n to 25% of the f
u
ll CFM rating of the air handler
or any
w
here in
b
et
w
een.
20.1.4 Autocycle Air Control
The A
u
tocycle Air Control adj
u
sts the positioning of
the discharge damper to control the
v
ol
u
me of air
discharged into the facility. The A
u
tocycle incl
u
des
u
p to 12 pre-set positions adj
u
sted
b
y potentiometers
mo
u
nted on the printed circ
u
it
b
oard.
Each pre-set position is controlled
b
y an exha
u
st
fan interlock req
u
iring t
w
o
w
ires per interlock. The
installer m
u
st connect the t
w
o
w
ires
b
et
w
een the
printed circ
u
it
b
oard on the make-
u
p air
u
nit and the
a
u
xiliary contacts of the exha
u
st fans. the exha
u
st
fan starters m
u
st incl
u
de a
u
xiliary contacts.
FIGURE 73: Air Handler Confi
g
urations
20.2 Remote Panel Options
The remote panel sho
u
ld
b
e mo
u
nted in the
conditioned space in a con
v
enient location for
controlling the air handler. Do not locate a remote
panel
w
hich contains temperat
u
re sensing controls in
an area that is directly affected
b
y this air handler or
another heat so
u
rce as it may interfere
w
ith the
operation of the air handler.
20.2.1
8
.3LS Remote Panel Dischar
g
e Air Tem-
perature Control (DAT)
The 8.3LS Remote Panel incl
u
des S
u
mmer/Off/
Winter s
w
itch and
b
lo
w
er,
bu
rner, and flame fail
u
re
indicators in a NEMA 1 style enclos
u
re and
discharge temperat
u
re set point.
Blo
w
er Indicator: Indicates the air handler is
s
u
pplying po
w
er to the main fan motor
v
ia the motor
controls.
B
u
rner Indicator: Indicates that the air handler has
s
u
pplied po
w
er to open the main f
u
el sh
u
t off
v
al
v
e.
Discharge Air
100%
Outside Air
25%-100%
Volume
Motorized
Profile
Damper
Discharge Air
100%
Outside Air
Variable
0%-80%
Return Air
Motorized
Profile
Damper
Variable
20%-100%
Outside Air
Discharge Air
Vol
u
matic
w
ith VFD
Make-Up Air (MUA)
Vol
u
matic Recirc
u
lating
Содержание TT Series
Страница 2: ......
Страница 4: ......
Страница 136: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 130 of 198 FIGURE 114 Regulator RV61 ...
Страница 167: ...SECTION27 TROUBLESHOOTING 161 of 198 ...
Страница 175: ...SECTION27 TROUBLESHOOTING 169 of 198 ...
Страница 176: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 170 of 198 27 7 2 Series 94 Field Service Checklist ...
Страница 177: ...SECTION27 TROUBLESHOOTING 171 of 198 ...
Страница 198: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 192 of 198 ...
Страница 202: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 196 of 198 ...
Страница 203: ...SECTION 28 THE WEATHER RITE TT SERIES WARRANTY 197 of 198 ...
Страница 204: ...TT SERIES INSTALLATION OPERATION AND SERVICE MANUAL 198 of 198 ...