background image

1

Operating instructions

Marine air conditioning plants
BlueCool A-Series Air handler

Valid for BlueCool A-Series as of change index B (2017 ->):

About this document

1.1 

Purpose of the document

This operating instructions are part of the prod-

uct and provides the user with information on 

the safe operation of the unit.

1.2 

Using this document

X

X

Before operating the unit, read this operating 

instruction and the supplementary sheet "Im-

portant Information on Operating and Instal-

lation Instructions".

X

X

Keep these operating instructions ready to 

hand.

X

X

Hand these operating instructions on to the 

following owner or user of the unit.

1.3 

Use of symbols and highlight-

ing

WARNING
Type and source of the risk
Result: non-observance can 

lead to severe or mortal inju-

ries.

X

X

Actions to protect yourself 

against risks.

CAUTION
Type and source of the risk
Result: non-observance leads to 

property damage.

X

X

Actions to protect yourself 

against risks.

EN

Содержание BlueCool A-Series

Страница 1: ...ad this operating instruction and the supplementary sheet Im portant Information on Operating and Instal lation Instructions X X Keep these operating instructions ready to hand X X Hand these operatin...

Страница 2: ...The air conditioning systems must ALWAYS be switched off during refuelling or while in a petrol station area 3 Description The BlueCool MyTouch is the standard control element for the BlueCool A Serie...

Страница 3: ...matic mode 6 Settings The symbols on the Home screen provide infor mation on the system status The symbols are explained in the table below Symbol Meaning 1 On Off 2 Temperature 3 Fan 4 Settings 6 Not...

Страница 4: ...the room temperature measured by the cabin temperature sensor Note The system only cools under the following conditions cabin tem perature 15 C Setpoint temper ature cabin temperature The system only...

Страница 5: ...to reduce the time interval or tap to increase the time interval The symbol marks the current selection X X Tap on the required time to set the time in terval X X Tap the Previous symbol to go to the...

Страница 6: ...ight Cabin temperature dark Shows the current cabin temperature at low brightness levels in areas with little am bient light Display off No display in standby mode Operation indicator An illuminated d...

Страница 7: ...al wiring defective Power circuit interruption short circuit Please contact your authorised Webasto Marine dealer n a No pc board output Fuse faulty or break short circuit in this electrical circuit P...

Страница 8: ...sions the German language is binding The telephone number of each country can be found in the Webasto service centre leaflet or the website of the respective Webasto representative of your country Web...

Отзывы: