Installation
|
2-13
Pilot Plus
XX200-00
6. Connect the terminal block plug into the respective alarm terminal block.
Alarm Relay Output
Note:
Refer to the
Cable Recommendations
section in the
Maintenance
chapter for information on the type of cables to be used for twisted-pair
connection.
The Alarm Relay output provides a control output to an external device,
which may be wired normally open or normally closed. Connect the external
device as follows:
1. Select the 3-Position Terminal Block Plug, part number F004802505 from
the Accessory Kit.
2. Route the appropriate wires from the external device to the unit.
3. Using wire strippers, remove approximately 0.25 in. (0.64 cm) from the
two wires.
4. Note the position of pin 1 on the terminal block.
5. Connect the wires from the external device in accordance with the pinout
data that follows.
Pin #
Name
1
Normally Closed
2 Common
3 Normally
Open
6. Connect the terminal block plug into the ALARM RELAY terminal block.