Installation
|
2-11
Pilot Plus
XX200-00
Alarm Inputs
Note:
Refer to the
Cable Recommendations
section in the
Maintenance
chapter for information on the type of cables to be used for twisted-pair
connection.
Alarm Inputs are wired directly into the Pilot Plus. There are two 16-position
terminal blocks labeled ALARM 1-16 and ALARM 17-32 on the rear panel.
Connect the alarms as follows:
1. Select the 16-Pin Terminal Block Plug, part number S56G0000004 from
the Accessory Kit.
Note:
There are four terminal block plugs. One for each 16-pin upper and
lower bank on the terminal blocks.
2. Route the appropriate wires from the alarms to the unit.
3. Using wire strippers, remove approximately 0.25 in. (0.64 cm) from the
two wires.
4. Note the position of pins 1, 9, 17 and 25 on the respective terminal blocks.
5. Connect the wires from the alarms to the plugs in accordance with the
pinout data that follows.
ALARM 1-16 Terminal Block Plug
Pin #
Name
Pin #
Name
1
ALARM 1
1
ALARM 9
2 GND 2 GND
3
ALARM 2
3
ALARM 10
4 GND 4 GND
5
ALARM 3
5
ALARM 11