The Control Equipment Status menu shows the status of the ventilation equipment in the building. The screens are
automatically updated as the status changes. Use the
UP
and
DOWN
arrow keys to scroll through the available menu
items in this category. Use the
PLUS
and
MINUS
keys to scroll through the device group numbers within each menu
item (device type).
Control Equipment Status Menu (Hot-Key)
Menu items for devices and equipment not installed are not shown.
Any device that has an
ON/OFF
status menu, may also have (SW ON) or (SW OFF) on the menu when the output
channel’s toggle switch is in a position that contradicts the expected on/off status.
The current ON/OFF status of an individual furnace group is shown (brooder and heater are similar).
CONTROL EQUIPMENT STATUS Z1-S02
Furnace Group #1: OFF
Fixed speed fan groups can only be
OFF
or
ON
. Variable speed fan groups can be
OFF
or
ON
at power settings that
range from 1 (minimum) to 60 (full on).
CONTROL EQUIPMENT STATUS Z1-S02
Vari-Side Fan Group #1: ON at 22 of 60
CONTROL EQUIPMENT STATUS Z1-S02
Sidewall Fan Group #1: OFF
CONTROL EQUIPMENT STATUS Z1-S02
Tunnel Fan Group #2: OFF
CONTROL EQUIPMENT STATUS Z1-S02
Vari-Side Fan Group #3: OFF
In house fog, cool pad and mister operation is controlled using temperature and one of four variable duty cycle
timers. The example below shows house fog Group number two (#2) is currently controlled by Duty Cycle timer four.
CONTROL EQUIPMENT STATUS Z1-S02
In House Fog Group #2, Duty Cycle 4: ON
Variable speed fans require a controller model with variable speed channels
or the ability to communicate with a variable speed expansion station.
CURRENT
STATUS
Use
RIGHT
arrow key to
scroll to this menu.
Brooders / Furnaces / Heaters
Fans
In House Fog, Cool Pads and Misters
Vari-Brooders and Vari-Heaters
The current ON/OFF status of an individual heater group is shown. If the heater is on, the current BTU output of the
hearter is shown.
CONTROL EQUIPMENT STATUS Z1-S02
VariBrooder #1: On at 121K BTU