APPENDIX 11 - Purge and Min. Vent Min/Max Settings
Building Purge Settings
This shows when no fans are installed except
Stir fans
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric
English
Metric
Eng
-
lish
Met
-
ric
Display Edit
Purge Time
0:00:00
0:00:00
9:00:00
N/A
0
4
Delay Time (Purge)
3:00:00
0:00:01
18:00:00
N/A
0
4
Humidity Setpoint (See Note 1)
100
0
100
1
0
4
Humidity Purge Time (See Note 1)
0:00:00
0:00:00
9:00:00
N/A
0
4
Delay Time (Humidity Purge) (See Note 1)
1:00:00
0:00:00
9:00:00
N/A
0
4
Purge Inhibit Temp LOW (See Note 2)
60.0
15.6
-60.0
-51.1
159.9
71.0
0.1
0
4
High (Purge Inhibit Temp) (See Note 2)
74
23.3
Low Temp + 0.1
160.0
71.1
0.1
0
4
Before purge raise Temperature to: (See Note 2)
70.0
21.1
SetPoint
Se
5.0
Setpoint
+ 2.7
0.1
0
4
Time to Abort Heat before Purge (See Note 2)
0:00
0:00
59:59
N/A
0
4
Note 1: Enabled only when Humidity Sensor is installed
Note 2: Enabled when a heater is installed with “Use During Heat Purge” set to Yes and Purge Time and Delay are non-zero
or Humidity Setpoint is 1% to 99% and Humidity Purge Time and Delay are non-zero
Minimum Vent Settings
This show when fans are installed other than
Stir fans
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric
English
Metric
Eng
-
lish
Met
-
ric
Display Edit
Minimum Vent Timer ON
0:00
0:00
59:59
N/A
0
4
Off (Minimum Vent Timer)
0:00
0:00
59:59
N/A
0
4
Min Vent #1 to #9
0
4
Age
0
0
900
1
0
4
On\Off times
0:00
0:00
59:59
N/A
0
4
Humidity Setpoint (See Note 1)
100
0
100
1
0
4
Humidity Purge Time (See Note 1)
0:00:00
0:00:00
9:00:00
N/A
0
4
Delay Time (Humidity Purge) (See Note 1)
1:00:00
0:00:00
9:00:00
N/A
0
4
Purge Inhibit Temp LOW (See Note 2)
60.0
15.6
-60.0
-51.1
159.9
71.0
0.1
0
4
High (Purge Inhibit Temp) (See Note 2)
74.0
23.3
Low Temp + 0.1
160.0
71.1
0.1
0
4
Before purge raise Temperature to: (See Note 2)
70.0
21.1
SetPoint
Se
5.0
Setpoint
+ 2.7
0.1
0
4
Time to Abort Heat before Purge (See Note 2)
0:00
0:00
59:59
N|A
0
4
Note 1: Enabled only when Humidity Sensor is installed and a Fan is set to a Purge mode
Note 2: Enabled when a heater is installed with “Use During Heat Purge” set to Yes and Humidity Setpoint is 1% to 99% and Humidity Purge
Time and Delay are non-zero