215
® 2018 Valco Companies, Inc.
Variable Brooder (Bird), Heater (VP Only)
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric English Metric English Metric Display
Edit
Use Sensors
ALL (0,0,0,0)
0
# of Sensors
1 (Only sensor #’s)
0
4
Lower Temp by
0.0
0.0
15.0
0.1
0
4
From x:xx to x:xx
00:00
00:00
24:00
N/A
0
4
Interlock Curtain Groups (See Note 1)
All (0,0,0,0,0,0)
0
9
1
0
4
Use During Heat Purge (See Note 2)
No
Yes or No
N/A
0
4
BTUs - Minimum / Maximum
0
0
999000
1000
0
4
Temp Target
68.0
20.0
-60.0
-51.1
159.9
71.0
0.1
0
4
OFF Actual
70.0
21.1
Target Temp +
0.1
160.0
71.1
0.1
0
4
Alarm When Heater is at MAX for
0:00:00
0:00:00
18:00:00
N/A
0
4
Shut Off on Alarm
No
No
Yes
N/A
0
4
Gas Regulator: Module
0
2
16
1
0
4
Channel:
0
1
12
1
0
4
Note 1: Enabled only when a “Side Curtain” or “Ridge Vent” is installed and “Heater to Curtain Interlock” is set to “Zone Interlock” or “All Zone
Interlock”
Note 2: Enabled only when a Humidity Sensor is installed, Fan set to purge, RH Stpoint less than 100 and purge time above 0
Menus that appear for Brooder (Bird), Heater (Hog) and Furnace
Enabled and Disabled (X means Enabled)
Zone All Zone No
Interlock
Inter
-
lock
Inter
-
lock
Use Sensors
X
X
X
On Temp/Off Temp Actual
X
X
X
On Temp/Off Temp Adjusted
X
X
X
Lower Temp by / From / To
X
X
X
Interlock Curtain Groups (See Note 1)
X
X
Use During Heat Purge (See Note 2)
X
X
X
BTUs / Has Pilot Light: (VP, non- Variable only)
X
X
X
BTUs - Minimum / Maximum (VP, Variable only)
X
X
X
Temp Target / Off (VP, Variable only)
X
X
X
Alarm When Heater is at MAX for (VP, Variable only)
X
X
X
Shut Off on Alarm
X
X
X
Gas Regulator: Module / Channel (VP, Variable only)
X
X
X
Note 1: Enabled only when a “Side Curtain” or “Ridge Vent” is installed and “Heater to Curtain Interlock” is set to “Zone Interlock” or “All Zone
Interlock”
Note 2: Enabled only when a Humidity Sensor is installed, Fan set to purge, RH Stpoint less than 100 and purge time above 0
APPENDIX 22 - Miscellaneous Device Min/Max Settings-continued