148
® 2018 Valco Companies, Inc.
Alarm history displays conditions or events that may cause an active alarm condition. The Error Detail is a long-term
record of any type of system, device or building abnormality that provides important information to help evaluate
system problems.
The alarm history stores up to 20 of the most recent alarms. An alarm record is created each time a new type of
alarm condition is detected. Most alarm conditions require multiple occurrences to activate the alarm relay. All alarm
records that are currently active or were previously active will always be displayed. If no key has been pressed for
one minute, the display will show the most recent alarm. Pressing
ENTER
while viewing an active alarm clears the
alarm condition and changes the display from active alarm to alarm history. Some alarms are automatically cleared
when the alarm condition is no longer detected.
Press
CANCEL
(3) three times (Home Screen) and then the
LEFT
arrow key to Alarm History. This will allow you to get
to the alarm screen from any other screen.
“Zone 0” alarms occur when an alarm relates to all zones (if applicable). For example, a possible hardware
problem would generate a Zone 0 alarm.
P
ossible Alarm Conditions on next page.
Alarm History
ALARM HISTORY FOR 12/20 AT 11:23
#01 Air #3 STA#01 CH#14 CNT 38 VALFFFB
Press the
PLUS
and
MINUS
keys to move through the HISTORY of alarms.
CANCEL
• If the control keeps displaying the Alarm History menu but does not display an active alarm, you
must use the PLUS or MINUS keys to scroll through the history and locate the active alarm.
• If the control is idle for over a minute and there is an active alarm, the control will return to the
screen above automatically.