APPENDIX 10 - Temperature Control Min/Max Settings
Temperature Control Settings
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric English Metric English Metric Display
Edit
Temp Setpoint (See Note 7 & 8)
70.0
21.1 -60.0 -51.1 160.0 71.1
0.1
0
2
Temp Control
Actual
Off
Actual *---------- Eff.
0
4
House Control Mode (Bird Only)
Growout2
“Brood”, Growout1, Growout2
0
4
Simulator Temperature
-55.0
-55.0
160
0.1
9
9
Ridge To Curtains (See Note 4)
No Interlock
“No Interlock” and “Interlock”
0
4
Heat to Curtains (See Note 5)
No Interlock
“No Interlock”, “Zone Interlock” & “All Zone Interlock”
0
4
Enter Tunnel Temp (See Note 3)
85.0
29.4 -60.0 -51.1 160.0 71.1
0.1
0
4
Exit Tunnel Temp (See Note 3)
80.0
26.6 -60.0 -51.1 160.0 71.1
0.1
0
4
Remain in Tunnel Time (See Note 3)
1:00:00
0:00:00
9:00:00
N/A
0
4
Enable Tunnel Entry. Outside Temp (Note 1 & 3)
0.0
0.0
0.0
0.0
75.0
23.9
0.1
0
4
Today’s Age (See Note 6)
0
0
900
1
0
4
Ramp Point #1 TO #12
0
4
Age
0
0
900
1
0
4
Temp
70.0
21.1
-60
-51.1
160
71.1
0.1
0
4
Temperature Ramp Offset
0.0
-12.0
+12.0
0.1
0
2
Floor Type (Hog Only)
Concrete
“Concrete” and “Other”
0
4
Close Curtains Below Outside Temp (See Note 2) -60.0 -51.1 -60.0 -51.1 160.0 71.1
0.1
0
4
Note 1: Enabled only an Outside Temp Sensor are installed and Power vented
Note 2: Enabled only when a Curtain and an Outside Temp Sensor are installed and Power vented
Note 3: Enabled only with a Fan installed and set to a Tunnel mode
Note 4: Enabled only when a Ridge Vent and a Curtain are installed
Note 5: Enabled only when a Curtain is installed and either a Heater, Furnace, or Brooder is installed
Note 6: If Temperature Ramp Table has values set, then changing age will cause Setpoint to change (See Note 8 & Ramp Table Theory)
Note 7: If Ramping is on then this is disabled
Note 8: Changing the Setpoint will cause the following values to change:
· Temperature Control Settings
· Temp Setpoint
Ramp Table Theory:
If Age #1 is zero or Animal Age is zero, then Ramping is Off and all
other values in Ramp table are ignored.
As Animal Age changes, the Temp Setpoint is changed to that
Age’s Setpoint in Ramp Table or incremented based on Ages and
Setpoints in Ramp Table (See Note 8)
If the Ramp Table Age is less than or equal to the previous Ramp
Table Age then that Setpoint and all additional Setpoints are
ignored and Ramping is turned off.
· Enter and Exit Tunnel Temp
Close Curtains Below Outside Temp
· Purge and Minimum Vent Settings
· Low and High Temp Inhibit
Before Purge Raise Temperature
· Sound Alarm When settings
· High Temp Exceeds (not Fixed)
· Low Temp Drops Below
· Fixed Fans – Stir, Sidewall, Tunnel, Ridge, Pit
· Heater Settings – Brooder, Furnace, Heater
· On/Off Temp
· Mister Settings – In House Fogger, Cool Pad Low/High, Mister
· Full On/Off Temp
· Cycle On Temps
· Curtain Inlets
· Open/Close Temps
· On/Off Temp
· Fans OFF at Curtain Opening of
· Variable Fans - Stir, Side, Tunnel, Ridge, Pit
· On/Off Temp
· Ramp Start Temp
· Full Power Temp
· Fans OFF at Curtain Opening of
*