155
® 2018 Valco Companies, Inc.
When the controller powers up, you have the ability to run some optional procedures before the controller starts to
control the environment of the building. These options include:
• Creating a new parameter set.
• Creating a copy of a parameter set from an existing parameter set, either on the same SD card or another
SD card.
• Changing the current Parameter Set used by the controller.
• Clearing the alarm records stored in memory.
• Clearing the current hours’ history record.
To access the Start Up Options, press
ENTER
a few seconds after the controller starts and the screen below is displayed.
Start-up Procedure Option:
Press ENTER to change (Displays for approximately 2 seconds)
If you are asked for a password when you press
ENTER
, you will need to enter the Options password before you can
continue with the options. See page 161 for information on the Options password.
ENTER
Start Up Options
*
The first option allows you to copy an existing Parameter Set, either to the same SD card or to another SD card. Press
ENTER
to skip this option or use the
PLUS
or
MINUS
key to set this option to YES to run the copy procedure
(see page
156 on Creating or Copying Parameter Sets, for more information on this procedure).
Start-Up Procedure Options: COPY PARMS----
Copy Parameter File on SD CARD? NO
The second option allows you to create a new Parameter Set or to change the Parameter Set used by the controller
to control the environment. Use the
PLUS
and
MINUS
key to set the number to an existing Parameter set, which will
be loaded, or to an unused number to have a new Parameter Set created. Press
ENTER
to save the new parameter
number and to continue to the next option.
See page 158 thru page <?>
for more information on Creating new
parameter sets or changing parameter sets.
Start-Up Procedure Options: Parameter Set
Load Parameter Set Number: 1
The third option allows the clearing of the 20-slot Alarm table stored in memory. Press the
PLUS
key to set the
option to YES, if you want to clear the memory table. Press
ENTER
to continue to the next option.
Start-Up Procedure Options: ALARM RESET
REMOVE all alarm records? YES
The fourth option allows the clearing of the current hour’s history table stored in memory. Press the
PLUS
key to set
the option to YES, if you want to clear the memory table. Press
ENTER
to continue to the next option.
Start-Up Procedure Options: HISTORY RESET
CLEAR HISTORY Collect Structure? YES
The third and fourth options only clear the alarm and history tables in memory. All alarm
records and history records stored on the SD card are retained.
+
ENTER
+
ENTER
+
ENTER
+
ENTER