160
® 2018 Valco Companies, Inc.
Changing Parameter Sets
Once there are multiple Parameter Sets set up, use the following steps to change the Parameter Set used to control
the environment.
1. Make sure the current parameters are saved:
a. Press the
CANCEL
key (3) three times.
b. Press the
DOWN
arrow key, to display the Revisions Date/Time screen.
c. Press the
ENTER
key (Writing PARAMETERS to Flash will be displayed).
2.
Restart the Controller
3. Press the
ENTER
key when the screen displays "Press
ENTER
to change."
a. This screen only appears for a few seconds shortly after the controller starts
StartUp Procedure Options:
Press ENTER to Change!
CANCEL
ENTER
4. If an Options password has been entered, enter the 8-digit password to access the Startup Options
menus. See "Password for Parameter Set Options"
on page 161
of this manual for more information.
StartUp Procedure Options: SET PASSWORD
Enter Options Password: 0xxxxxxxx
5. Leave "Copy Parameter File on SD CARD?" set to NO and press
ENTER
.
StartUp Procedure Options: COPY PARMS----
Copy Parameter File on SD CARD?: NO
6. Press the
PLUS
and
MINUS
keys to select an existing Parameter Set number to be used.
a. If you select the number of a nonexistent Parameter Set, a new, blank parameter set will be
loaded into the controller memory and you will need to set everything up from scratch.
ENTER
StartUp Procedure Options: Parameter Set
Load Parameter Set Number: 1
7. Press
ENTER
to continue.
8. Optional: Press the
PLUS
key to set “REMOVE all alarm records?” to Yes if you want to clear the current Alarm
table in the controller.
a. Only the 20-slot alarm table in memory is cleared. The Alarm Detail records, which are stored on
the SD card, will not be deleted.
StartUp Procedure Options: ALARM RESET
REMOVE all alrm records?: NO
9. Press
ENTER
to continue.
10. Optional: Press the
PLUS
key to set “CLEAR HISTORY Collect Structure?” to Yes if you want to clear the current
hour’s history record stored in memory.
a. Only the current hour’s history in memory is cleared. All previous history records, which are
stored on the SD card, will not be deleted.
StartUp Procedure Options: HISTORY RESET
CLEAR HISTORY Collect Structure?: NO
11. Press
ENTER
to continue.
12. The controller will now load the selected parameter set and continue the normal startup operations.
ENTER
+
-
or
ENTER
ENTER
+
+
*