APPENDIX 19 - Ridge Vent Min/Max Settings
Ridge Vent
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric English Metric English Metric Display Edit
Use Sensors
ALL (0,0,0,0)
0
# of Sensors
installed
1 (Only sensor
#’s)
0
4
Open Temp
72..0
22.2
-59.9
-51.0 160.0
71.1
0.1
0
4
Close Temp
68.0
20.0
-60.0
-51.1
On Temp - 0.1
0.1
0
4
Open
7
17
1
250
1
0
4
Pause (Open)
0:01:00
0:00:10
9:00:00
N/A
0
4
Close
7
17
1
250
1
0
4
Pause (Close)
0:01:00
0:00:10
9:00:00
N/A
0
4
Response Mode
Standard
“Standard” and “Aggressive”
0
4
Full Opening Size
14
35
1
250
1
0
4
Full Open Travel Time
0:45
0:05
59:59
N/A
0
4
Full Close Travel Time
0:45
0:05
59:59
N/A
0
4
Purge Opening Size (See Note 1)
4
10
0
250
1
0
4
Interlock Curtain Groups (See Note 2) All (0,0,0,0,0,0)
0
9
1
0
4
Perform Re-Sync at
0:00
0:00
24:00
N/A
0
4
Note 1: Enabled only if Purge On/Off times are greater than 0:00:00, if power building then Humidity Sensor needs to be
installed and one fan has to run during Purge and Humidity Purge Time and Delay has to be greater than 0
Note 2: Enabled only if Side Curtain installed and Ridge to Curtain Interlock set to Interlock
Menus that appear for Ridge Vent
Enabled and Disabled (X means Enabled)
Natural
No
Tunnel
Inter
-
lock
Inter
-
lock
Use Sensors
X
Open / Close Temp
X
Open / Pause
X
Close / Pause
X
Response Mode
X
Full Opening Size
X
X
Full Open Travel Time
X
X
Full Close Travel Time
X
X
Purge Opening Size (See Note 1)
Note 1 Note 1
Interlock Curtain Groups (See Note 2) Note 2
Perform Re-Sync at
X
X
Note 1: Enabled only if Purge On/Off times are greater than 0:00:00, if power building then Humidity Sensor needs to
be installed and one fan has to run during Purge and Humidity Purge Time and Delay has to be greater than 0
Note 2: Enabled only if Side Curtain installed and Ridge to Curtain Interlock set to Interlock