PA-69
Shielded wire MUST go to EARTH GROUND
The electronic water meter sensor is made to fit on the Badger™ flow meter RCDL 25 (or a compatible
unit) as shown below. Any other orientation may cause inaccurate readings and early
FAILURE.
The water meter hooks up to a three-connection input. If you use another meter with two electrical
connections, wire through IN and GND and verify that the control is reading the signal. Improper
connections or incompatible sensors may ground out the input/output board and cause noticeable
controller malfunction until the wiring is corrected OR DAMAGE TO THE OTHER WATER METER
MAY OCCUR.
Digital Meter Wiring Example
PA-69 (Digital) WATER METER
Water Flow (Counter) Meters
BADGER COUNTER METER
Wire as shown in the diagram
to the right.
THIS IS A DRY
CONTACT, DO NOT ATTACH
ANY OF ITS WIRES TO +12V.
GND
AIN14
GND
AIN13
GND
AIN12
GND
AIN11
GND
AIN10
GND
AIN9
GND
AIN8
GND
AIN7
GND
DIN6
+12V
GND
DIN5
+12V
GND
DIN4
+12V
GND
DIN3
+12V
GND
DIN2
GND
DIN1
RED
BLACK
Shielded wire MUST go to EARTH GROUND
DWYER COUNTER METER
Wire as shown in the diagram
to the right.
THIS IS A DRY
CONTACT, DO NOT ATTACH
ANY OF ITS WIRES TO +12V.
BOTH Counter Meter Wiring Examples