APPENDIX 18 - Side Curtain Min/Max Settings
Side Curtain Settings
Defaults
Min
Max
Steps By
English Metric English Metric English Metric English
Metric
Use Sensors
ALL (0,0,0,0)
0
# of Sensors
installed
1 (Only sensor #’s)
Open Temp
72..0
22.2
-59.9
-51.0 160.0
71.1
0.1
Close Temp
68.0
20.0
-60.0
-51.1
On Temp - 0.1
0.1
Open
10
25
1
250
1
Pause (Open)
0:03:00
0:00:10
9:00:00
N/A
Close
10
25
1
250
1
Pause (Close)
0:03:00
0:00:10
9:00:00
N/A
Maximum Opening (See Note 8)
0
0
250
1
Below Temp
Setpoint
Setpoint
Se 40
degrees
0.1
Static Pressure Pause Timer (See Note 4)
0:00
0:00
1:00
N/A
Operate as (See Note 1 and 3)
Temp Natural Only
“Temp Natural Only”, “Temp Natural/Temp Tunnel”,
“Temp Natural/Static Tunnel”, “Temp Tunnel Only”,
“Static Natural Only”, “Static Natural/Temp Tunnel”,
“Static Natural/Static Tunnel”, “Static Tunnel Only”
Tunnel Fans ON #01 to #09
0 to 8
0
9
1 or 0.5
Tunnel Fans Open - #01 default is 0
48.0
121
0.0
0
250.0
250
0.1
1
Tunnel Fan Interlocks
All Fans
Interlock up to 9 installed fans that have “Use for Pro
-
portional Control” set to “Yes”, except Stir fans
Tunneling Open Sizes are:
Proportional
Proportional or Stepping
Response Mode
Standard
“Standard” and “Aggressive”
Full Opening Size
48
121
1
250
1
Full Open Travel Time
6:00
0:05
59:59
N/A
Full Close Travel Time
6:00
0:05
59:59
N/A
Purge Opening Size (See Note 2)
6
15
0
250
1
Pre-Open Timer (See Note 4)
0:00
0:00
1:00
N/A
Exercise Delay Days (See Note 5)
0
0
30
1
Perform Exercise at (See Note 6)
0:00
0:00
24:00
N/A
Number Hours 50% Open (Note 7)
0
0
250
1
Tunnel Entry Size/Exit Size
0
0
Full Open size
1
Perform Re-Sync at
0:00
0:00
24:00
N/A
Note 1: Enabled only if Static Pressure sensor installed or a fan installed and Tunnel is part of Operating Mode
Note 2: Enabled only if Purge On/Off times are greater than 0:00:00, if power building then Humidity Sensor needs to be
installed and one fan includes Purge and Humidity Purge Time and Delay has to be greater than 0 and Humidity Purge
Setpoint is between 1 and 99
Note 3: Static Modes will only show if Static Pressure Sensor Is Installed
Note 4: Enabled only if Static Pressure sensor installed and Operating mode includes Static Natural
Note 5: Enabled only if Operate As includes Temp Natural
Note 6: Enabled only if Exercise Delay Days is greater then 0
Note 7: Enabled only in Tech Security mode
Note 8: Enabled only when attached to Position Sensor that is calibrated, alarm is enabled and not alarming
See next page for a table showing which settings are enabled/disabled based on the Operate As setting.