144
® 2018 Valco Companies, Inc.
This menu item displays the sensor input as interpreted by the controller.
You must have a device installed on an input before that input can be tested.
This is designed for use by technicians when troubleshooting controller components or sensors. Select which input
channel to test by scrolling through the input numbers with the
PLUS
and
MINUS
keys. After you’ve selected an input
by pressing ENTER, the display shows the value of the input signal as reported by the analog to digital converter. The
value will be a five digit number such as 34056. The controller takes another reading each time you press
ENTER
.
TEST INPUT of AIR SENSOR #01
Input reading 34285 - ENTER to READ
+
ENTER
This menu item displays the On/Off status of the output relays. Select which station/module to test by scrolling
through the station numbers with the
PLUS
and
MINUS
keys. After you’ve selected a number by pressing
ENTER
, the
display changes to show you the channel numbers of the output relays which are currently on. Flip the toggle switch
to verify a channel is working.
If the display cannot show all the channel numbers of output relays turned on, pressing the
PLUS
and
MINUS
keys to narrow down the channels displayed in increments of ten.
OUTPUTS are ON for STA 01 -Press ENTER 1 2 4 7 11 12 16 18 21 24 31 32
OUTPUTS are ON for STA 01 -Press ENTER 11 12 16 18 21 24 31 32
OUTPUTS are ON for STA 01 -Press ENTER
21 24 31 32
+
+
Test Inputs
Test Output Status
Test Control Center Hardware - continued