140
® 2018 Valco Companies, Inc.
VariLights Settings-continued
DEVICE / EQUIPMENT SETTINGS
Z1-S01
PRESS ENTER TO VIEW SETTINGS
VARILIGHTS GROUP #1 TIMER SETTING Z1-S01
Minimum Ramp ON Percent: 20%
Minimum Ramp On Percent
The “Minimum Ramp On Percent” is the beginning light intensity percentage when the device turns on and starts
ramping up, and the lowest percentage the intensity level will ramp down to before it shuts off.
This setting is used
for all the schedules set up for this device
. The range is from 0% to 100%. Note: if the Light Intensity Percentage of
the schedule is lower than the Minimum Ramp On Percent, there will be no ramping for that schedule. The intensity
level will be set to the schedule’s Intensity setting at the On time and turned off at the Off Time.
CONTROL
SETTINGS
ENTER
OFF to ON Ramp Time[minutes]
Set this value to the number of minutes the device should take to ramp up from Minimum Ramp On Percent to a
schedule’s set Intensity percentage. The device will turn on to the Minimum Percent at the On time, then take this
many minutes to ramp up to the set intensity.
This setting is used for all the schedules of this device
. The range is
from 0 minutes (no ramping) to 90 minutes. Note: the actual ramp time could be shorter if the difference between
the On time and the Off time is shorter than the time it takes to ramp up, then ramp down.
DEVICE / EQUIPMENT SETTINGS
Z1-S01
PRESS ENTER TO VIEW SETTINGS
CONTROL
SETTINGS
ENTER
VARILIGHTS GROUP #1 TIMER SETTING Z1-S01
OFF to ON Ramp Time [Minutes]: 45
ON to OFF Ramp Time[minutes]
Set this value to the number of minutes the device should take to ramp down from the schedule’s set Intensity
percentage to the Minimum Ramp On Percent before the device shuts off. The device will start ramping down this
many minutes before the Off time and reach the Minimum Percent at the Off time, then shut off.
This setting is used
for all the schedules of this device
. The range is from 0 minutes (no ramping) to 90 minutes. Note: the actual ramp
time could be shorter if the difference between the On time and the Off time is shorter than the time it takes to ramp
up, then ramp down.
DEVICE / EQUIPMENT SETTINGS
Z1-S01
PRESS ENTER TO VIEW SETTINGS
CONTROL
SETTINGS
ENTER
VARILIGHTS GROUP #1 TIMER SETTING Z1-S01
ON to OFF Ramp Time [Minutes]: 30