203
® 2018 Valco Companies, Inc.
APPENDIX 14 - Sensor Min/Max Settings
Air Sensors
(including the Outside Sensor (#13))
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Air Sensor #X Cable Length
100
30
1
9999
1
0
1
Air Sensor #X Wire Diameter
24
0.6
English allows only “16”, “18”, “20”, “22” & “24”
Metric allows only “0.5”, “0.6”, “0.7”, “0.8”, ‘0.9”, “1.0”, “1.1” & “1.2”
0
1
Air Sensor #X Temperture Offset
0.0
-15
-8.3
15
8.3
0.1
0
1
Air Sensor #X Location (Bird only)
Brood
“Brood”, “Growout1”, “Growout2”
0
1
Air #xx Use for Wind Speed
Yes
Yes/No
0
1
Air #xx Cal Values (Note 1)
550/90
400/40
1200/200
1
0
1
Note 1: Only enabled if Use for Wind Speed is Yes
Note: Outside Sensor does not have Location or Wind speed
Air Sensors Shared
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Air Sensor #X Location (Bird only)
Brood
“Brood”, “Growout1”, “Growout2”
0
1
Air Sensor Shared uses the values from the Air Sensor it is attached to but it does have its own Location setting for Birds
Humidity Sensors
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Humidity #xx Cal 1
10485
0
Cal Value 2 - 1
1
0
1
Cal 2
51118
Cal Value 1 + 1
65535
1
0
1
Static Pressure Sensors
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
ADC Cal 1
6554
0
ADC Cal 2
1
0
4
ADC Cal 2
58982
ADC Cal 1
65535
1
0
4
WC Cal 1
0.000
0.000
WC Cal 2
0.001
0
4
WC Cal 2
0.250
WC Cal 1
6.500
0.001
0
4
Feed Sensors
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Minimum Amps
0.1
0.0
25.0
0.1
0
4
Cal Value
100
0
999
1
0
4
Water Meter
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Cal Value (PPG) or (PPL)
25.0
0.0
99.9
0.1
0
4