Error
Code
Message
Action
39
Drum Motor Power OFF Error.
Go to Drum Motor Diagnostics
and turn the Drum Motor OFF
and check the status byte. If not
responsive may be a problem
with the motor, cable or sensor.
40/43
Drum Motor Fails To Move.
41/44
Drum Motor Position Error.
Possible bad control board. Go
to L/S CTRL Board Diagnostics
and turn the Drum Motor
ON/OFF using the buttons in
the Digital Inputs column.
Notice if sensors turn ON/OFF
(above). If functional, go to
Drum Motor Diagnostics and
Learn Positions/perform position
tests. May indicate a bad
motor.
42/45
Drum Motor Temperature Too High.
Possible Motor Defect.
46
Sample Door NOT Closed.
See 4, 5, 6 above
47
Light Curtain Blocked.
Check light curtain for
obstruction. Go to L/S CTRL
Board Diagnostics, block the
beam with your hand and
notice if the sensor turns
ON/OFF in the Digital Inputs
column.
48
Sample Door NOT Closed.
See 4, 5, 6 above
Содержание HVI1000
Страница 2: ......
Страница 24: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 1 3 08 Introduction Page 1 10 ...
Страница 50: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 3 3 08 System Startup Page 3 16 ...
Страница 174: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 8 5 08 System Diagnostics Page 8 38 ...
Страница 192: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 10 3 08 Maintenance Page 10 6 ...
Страница 230: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 12 7 07 Appendix Page 12 30 ...
Страница 236: ...USTER HVI 1000 Instruction Manual Uster Technologies Inc Chapter 13 3 08 Index Page 13 6 W Warm Up Color Head 8 6 ...
Страница 238: ......