APPENDIX A: TECHNICAL SPECIFICATIONS
HF25D DC RESISTANCE WELDING SYSTEM
A-2
990-333
Performance Capabilities
Number of Weld Schedules
...................................................................................................................100
Programmable Weld Periods:
Squeeze
.................................................................................................................................0 - 999 ms
Upslope
1 .................................................................................................................................0 - 99 ms
Weld
1
...................................................................................................................................0 - 99 ms
Downslope
1 ............................................................................................................................0 - 99 ms
Cool ...................................................................................................................................0 - 99 ms
Upslope
2
................................................................................................................................0 - 99 ms
Weld
2
...................................................................................................................................0 - 99 ms
Downslope
2 ............................................................................................................................0 - 99 ms
Hold .................................................................................................................................0 - 999 ms
Weld Head System Compatibility
Force Fired, Foot Actuated
Force Fired, Single Valve Air Actuated
Non Force-Fired, Single Valve Air or Cam Actuated
Force Fired, EZ Air Kit
Weld Energy Limits Monitoring
Energy Limit Mode: Terminate weld energy upon reaching the programmed current, voltage,
power or resistance alarm level.
Weld Pre-Check Mode: Inhibit second weld pulse when first test pulse exceeds programmed limits.
Measurement Parameters: Current, voltage and power.
Measurement Selection: Peak or average.
Measurement Range and Accuracy:
Parameter
Range
Accuracy
Current
0.01 - 2.4 kA
± (2% of s2A)
Voltage
0.05 - 9.999 V
± (2% of s0.02V)
Power
0.01 - 9.999 kW
± (5% of s10W)
Limit Ranges: Same as the measurement ranges
Alarms: Display alert and four programmable AC/DC relay contact outputs.
Содержание HF25A
Страница 9: ...HF25D DC RESISTANCE WELDING SYSTEM 990 333 ix ...
Страница 10: ......
Страница 20: ......
Страница 84: ...CHAPTER 6 CALIBRATION HF25D DC RESISTANCE WELDING SYSTEM 990 333 6 4 Final Calibration Setup ...
Страница 113: ......
Страница 129: ......
Страница 153: ......
Страница 171: ......