APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
E-22
990-333
Command
SYSTEM
<crlf>
LIGHT {
light_value
}
<crlf>
BUZZER
{ OFF | ON }
<crlf>
LOUDNESS {
loudness_value
}
<crlf>
DISPLAY
{ PEAK | AVG }
<crlf>
SWTYPE
{ MECHANICAL | OPTO | PLC }
<crlf>
SWSTATE
{ OPEN | CLOSED }
<crlf>
CTTYPE
{ MECHANICAL | OPTO | PLC}
<crlf>
CTSTATE
{ OPEN | CLOSED }
<crlf>
FIRESW
{ AUTO | REMOTE | NONE }
<crlf>
FIRESW
{ AUTO | OPTO | NONE }
<crlf>
GRAPH
{ OFF | ON }
<crlf>
WELDABORT
{ OFF | ON }
<crlf>
DEBOUNCE
{NONE | 10 | 20 | 30 }
<crlf>
<lf>
Control State
Any
Description
Reports the current settings of the Control system parameters.
light_value
is a number 0 to 99 for brightness of the LCD. 0 is dark and 100 is the
brightest.
loudness_value
is a number 0 to 99 for buzzer loudness. 0 is off and 100 is the loudest.
Command
ALARM
error_message
<crlf><lf>
Control State
Any
Description
Identifies the current error condition of operation of the Control. May be in response to the
ALARM READ
command sent by the host, or may be sent as a result of an error condition
occurring in the Control.
error_message
is a text string describing the error message, which is
the same error message that is displayed to the screen.
Command
SYNC
<crlf><lf>
Control State
Any
Description
The Control return SYNC command back to the host computer when the SYNC command is
received from the host computer.