CHAPTER 5. MAINTENANCE
HF25D DC RESISTANCE WELDING SYSTEM
5-6
990-333
Alarm Message
Description
Corrective Action
NO WELD
TRANSFORMER
DETECTED
Cable connecting the Control and Power
PCB’s is open.
Cable connecting the Power PCB to the
Weld Transformer is open.
Verify installation of the welding
transformer/rectifier module connections.
POWER 1
GREATER THAN
UPPER LIMIT
Actual weld power is greater than the
user set Upper Limit value for Weld1.
Weld splash can cause the actual weld power to
exceed the user set Upper Limit for Weld1. Add
upslope to reduce weld splash.
Reset the Upper Limit for Weld1 to a larger
value.
POWER 2
GREATER THAN
UPPER LIMIT
Actual weld power is greater than the
user set Upper Limit value for Weld2.
Weld splash can cause the actual weld power to
exceed the user set Upper Limit for Weld2. Add
upslope to reduce weld splash.
Reset the Upper Limit for Weld2 to a larger
value.
POWER 1 LOWER
THAN LOWER
LIMIT
Actual weld power is less than the user
set Lower Limit value for Weld1.
Weld splash can cause the actual weld power to
drop below the user set Lower Limit for Weld1.
Add upslope to reduce weld splash. Reset the
Lower Limit for Weld1 to a smaller value.
POWER 2 LOWER
THAN LOWER
LIMIT
Actual weld power is less than the user
set Lower Limit value for Weld2.
Weld splash can cause the actual weld power to
drop below the user set Lower Limit for Weld2.
Add upslope to reduce weld splash.
Reset the Lower Limit for Weld2 to a smaller
value.
POWER
TRANSISTOR
OVERHEATED
The power dissipated by the power
transistors has exceeded the HF25/26
specified capability.
Reduce duty cycle.
Reduce weld time.
PROCESS STOP ON
CONTROL
SIGNALS INPUT
The Process Stop signal on the
CONTROL SIGNALS connector has
been activated, immediately terminating
weld current.
Remove the Process Stop activating signal from
the CONTROL SIGNALS connector.
SAFE ENERGY
LIMIT REACHED
The HF25/26 internal power dissipation
has exceeded the HF25/26 specified
capability.
Reduce duty cycle.
Reduce weld time.
SCHEDULES ARE
RESET
User programmed the HF25/26 to
automatically reset all 100 weld
schedules to their factory set default
values.
CAUTION:
Be careful when using the MENU
default features. There is no way to restore a
default action.