APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
E-6
990-333
Command
POWER
<crlf><lf>
Control State
Any
Description
Requests the Control to report the sampled Current data of the last weld. Control shall return
with POWER report. See POWER command under Control Originating Commands section.
Command
COUNTER
{
TOTAL | HIGH | LOW | GOOD}
<crlf><lf>
Control State
Any
Description
Requests the Control to return the Control weld counter contents.
TOTAL returns the total number of weld counter.
HIGH returns the out of limits high counter.
LOW returns the out of limits low counter.
GOOD returns the within limits counter.
Command
REPORT
{
OLD
|
NEW
}
number
<crlf><lf>
Control State
Any
Description
Requests the Control to send the weld report.
OLD
: requests to send the number of oldest weld reports since the last data collection. The
reported weld data will be erased.
NEW
: requests to send the number of newest weld reports. All the weld data will be erased
after reported.
number:
the number of weld data to be sent.
If the number is greater than the number of weld data in the buffer, less than the number of
weld data will be sent. There must be a space between two fields.
Command
STATE {READ | RUN | MENU | MONITOR
}<crlf><lf>
Control State
Any
Description
Commands the Control to identify its current state ("READ" keyword, see STATE under
CONTROL ORIGINATED COMMANDS section) or go to either RUN state or PROGRAM
state.
Command
LOAD
{
schedule_number
}<crlf><lf>
Control State
RUN state
Description
Selects the schedule_number as the currently loaded schedule. schedule_number may be any
number from 0 to 99. There must be a space between LOAD and schedule_number.