APPENDIX D: LVDT OPTION
HF25 DC RESISTANCE WELDING SYSTEM
D-10
990-333
Scrolling Through Fields on the Screen
1
Press the
SCHEDULE
button to scroll
left
↔
right across the columns.
2
Pressing the
VW
buttons to scroll up
or down the rows on the screen.
Example
: Going down 2 rows, and right
one column highlights
DISPC HI LIM
.
LVDT
POSITION
+092 0000000
LO
LIM
HI
LIM
LAST
INITIAL
+000
000
+000
CONT
FINAL
+000
+000
+000
DISPLC
+000
000
+000
XX%
STOP ENERGY AT
000
XXXX
IN/1000
NEW ELECTRODE:
IS SET
VW
Scroll, SCHEDULE Select, RUN Run
Set New Electrodes to “Zero”
The LVDT must have a
zero
reference point (for example, when the two electrodes touch each other,
there is
zero
distance between them). All distances calculated by the LVDT are measured from this
zero
. When you change electrodes in your weld head or agressiveley clean the electrodes, the electrodes
may not be in the same exact position as the old electrodes, so
zero
may no longer be the same, therefore
you must set a new
zero
. There are two ways to set a new
zero
: Either perform the quick calibration
procedure detailed above or perform the new zero procedure detailed below. The preferred method is to
set a new zero and recalibrate as detailed above.
To set a new zero
without
recalibration:
1
From the
LVDT
keys section on the
front panel, press the
NEW
ELECTRODE
key and the screen on
the right appears.
2
During the next weld, the initial
position will be set to 0.
LVDT
POSITION
+092 0000000
LO
LIM
HI
LIM
LAST
INITIAL
+000
000
+000
CONT
FINAL
+000
+000
+000
DISPLC
+000
000
+000
XX%
STOP ENERGY AT
000
XXXX
IN/1000
NEW ELECTRODE:
NEXT WELD xx
SCHEDULE or DISTANCE Edit, RUN Run
3
The screen should now show
NEW ELECTRODE: IS SET.
Changing from Inches to Millimeters (
MM
)
Before
programming LVDT screens, select
inches (
IN
) or millimeters (
MM
) as your units of
measurement. The default is
IN
. To change to
MM
:
1
Press the
VW
buttons to scroll down
to the
STOP ENERGY AT
line.
LVDT
POSITION
+092 0000000
LO
LIM
HI
LIM
LAST
INITIAL
+00.00
00.00
+00.00
STOP
FINAL
+00.00 +00.00 +00.00
DISPLC
+000
000
+000
XX%
STOP ENERGY AT
000
XXXX
IN/1000
NEW ELECTRODE:
IS SET
SCHEDULE or DISTANCE Edit, RUN Run
2
Press the
SCHEDULE
key to scroll right to
highlight
IN/1000
.
3
Press the
PEAK/AVERAGE
key to change to
MM
. This will change all fields to mm
.
Limits
and last measurement data will be zeroed.