APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-15
Control Originated Commands
These are the commands sent from a Control to a host computer.
Command
STATUS
state_name
<crlf><lf>
Control State
Any
Description
Identifies the current status of the weld data buffer. May be in response with
“OK”
or
“OVERRUN.” “OK”
means that the Control weld buffer did not over-run since the last data
collection and all the data are intact.
“OVERRUN”
means that the Control weld buffer did
over-run since the last data collection and only the latest 1500 weld data are available to
report.
Command
TYPE
type, release numbers, revision letters
<crlf><lf>
NOTE:
HF25 software
lower
than version
1.29
will not display release number or revision
letter.
Control State
Any
Description
Returns “HF25 1.29L” for a HF25.
Command
COUNT
number
<crlf><lf>
Control State
Any
Description
Returns the number of weld data available in Control. The total number of weld data that the
Control holds in the buffer is 1,500.
Command
SCHEDULE
schedule_number
<crlf><lf>
Control State
Any
Description
Returns the current schedule number to the host. schedule_number may be any number from
0 to 99.