APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
E-2
990-333
A terminating resistor assembly is supplied with the unit. If only one unit is connected to the host, the
terminating resistor assembly must be installed in that unit. If multiple units are connected to the host,
only one unit (the unit furthest from the host) must have the terminating resistor assembly installed.
RS-232 Serial Connector Information
The serial port pin assignment is as follows:
Host settings
Baud Rate
1.2k, 2.4k, 4.8k, 9.6k, 14.4k, 19.2k, 28.8k (set on the unit)
Data bits
8
Stop bit
1
Parity
None
NOTES:
•
The host must be set to the same baud rate as the unit. The computer hardware and operating
system needed to support communication depends upon the RS-485 adapter (or converter box)
used.
•
For a microprocessor-based conversion (such as the Edgeport USB converter from Inside
Outside Networks), the host computer should be at least a Pentium II-233 running Windows 98,
Windows ME, Windows 2000, Windows XP or Windows NT 4.0. For a hardware-based
converter without an internal microprocessor (such as the Telebyte model 285), the host
computer should be at least a Pentium III-550 running Windows 98, Windows ME, Windows
2000, Windows XP or Windows NT 4.0.
#1 – Not Used
#2 -- TXD (Transmit Data)
#3 – RXD (Receive Data)
#4 – DSR (Data Set Ready)
#5 -- SGND (Signal Ground)
#6 -- DTR (Data Terminal Ready)
#7 -- CTS (Clear to Send)
#8 -- RTS (Request to Send)
#9 -- RI (Ring Indicator)