![Unitec Peco HF25A Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/unitec-peco/hf25a/hf25a_user-manual_844192102.webp)
APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
HF25D DC RESISTANCE WELDING SYSTEM
990-333
B-13
Standard Air Valve Driver Output
Function
The Control supplies a switched 24 VAC output to drive the air valve solenoid of a standard Unitek 24
VAC air actuated weld head.
Connections
Connect the weld head air valve solenoid cable to the four-pin
AIR VALVE DRIVER
connector on the
connector box. The mating connector is an AMP type 206429-1, using cable clamp AMP type 206358-
2. The two male pins used are Amp type 66361-2.
Standard Air Valve Driver Output Schematic Diagram
Standard AIR VALVE DRIVER Connector Pin Assignment Summary
Signal Destinations
Pin
No.
Name Type
TB
Control
Board
Max
Voltage
Max
Current
I/O
Comments
1
AC HEAD
AC.
1-8
J1-8
24VAC
3A
O
Air valve drive
2
AC HEAD
AC
1-9
J1-9
24VAC
3A
O
Air valve drive return