-Shenzhen Guanhong Automation Co.,Ltd.-
SZGH-CNC1000MDb Series
- 166 -
412
Teeth of SP_Motor (<P413)
1
413
Teeth of SP_Encoder (>P412)
1
414
Follow-Up of A Axis[7:X, 8:Y, 9:Z]
1
Note: System inner parameters cannot be changed.
Explanation about Axis Parameter:
1,Switch Type for Feed-Rate [0: Key, 1: Band Switch]
It is set switch type of Feed-Rate, Rate of Feeding axes.
0: Keys of “Feed Rate+” & “Feed Rate-” in Panel for adjust rate of feeding speed;
1: External Band switch for Feed-Rate. Port for external band switch is at CN11 plug, Pins are
VDK0,VDK1,VDK2,VDK3. Total are 16 gears
2,Switch Type for SP-Rate [0: Key, 1: Band Switch]
It is set switch type of SP-Rate, Rate of SP_Speed.
0: Keys of “SP Rate+” & “SP Rate-” in Panel for adjust rate of spindle speed;
1: External Band switch for SP-Rate. Port for external band switch is at CN11 plug, Pins are
VDS0,VDS1,VDS2,VDS3. Total are 16 gears
3,Max Travel in X_Negative direction (mm)
4,Max Travel in X_Positive direction (mm)
5,Max Travel in Y_Negative direction (mm)
6,Max Travel in Y_Positive direction (mm)
7,Max Travel in Z_Negative direction (mm)
8,Max Travel in Z_Positive direction (mm)
9,Max Travel in A_Negative direction (mm)
10,Max Travel in A_Positive direction (mm)
These parameters are set for max travel in negative direction/in positive direction of feeding
axes when soft-limitation is valid, which is based on machine coordinate system.unit: mm.
11,SP_Braking Time (10ms)
It is the braking time of spindle,also holding time of output M05. the shorter it is,the faster the
brake is. Unit: 10ms.
12,SP_Braking is Long Signal [0: No,1: Yes]
It is set for signal mode of SP_Braking. 1: Long signal, 0:short signal. It depends on braking
mode of spindle system.
13,Soft-Limitation is valid [0:Yes, 1: No]
It is bit parameter, set for if soft-limitation is valid of each feeding axis.
Bit
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Axis
-
-
-
-
YS XS
C
-
-
B
A
Z
Y
X
-
-
0: means soft-limitation is valid , 1: means invalid. Example: soft limit of X-axis is invalid,
P11= 00000100. Suggest all soft limit are valid even if CNC is fixed with hardware limit switches.
D12=1: don’t limit when use MOVE code
D14=1: don’t limit when ATC
D15=1: Save incremental coordinate even if power off, 0 means not.
14,X_Reverse Backlash Compensation (um) 15,Y_Reverse Backlash Compensation (um)
16,Z_Reverse Backlash Compensation (um) 17,A_Reverse Backlash Compensation (um)
It is the value of reverse backlash compensation of each one feeding-axis alone, When
direction of feeding-axis movement is changed ,system will make compensation with the value
automatically. Unit: um
18,X_Direction [1:normal, 0: Reverse]
19,Y_Direction [1:normal, 0: Reverse]
20,Z_Direction [1:normal, 0: Reverse]
21,A_Direction [1:normal, 0: Reverse]
It is for set the direction of each one feeding-axis. 1: Direction of feeding-axis is same to
direction of code; 0: Direction of feeding-axis is opposite to direction of code.