-Shenzhen Guanhong Automation Co.,Ltd.-
SZGH-CNC1000MDb Series
- 158 -
500-32000.when the value is less than 500,it is invalid.
25,G00 Speed when dry (mm/min) [>10]
It is the speed of G00 when when handwheel start program for simulate. it is invalid when the
value is less than 10.
25-1,Start Speed when dry with Handwheel (mm/min) [>5]
It is Starting speed of G00 when when handwheel start program for simulate. it is invalid
when the value is less than 5.
26,X_Max Speed with Handwheel (mm/min) 27,Y_Max Speed with Handwheel (mm/min)
28,Z_Max Speed with Handwheel (mm/min) 29,A_Max Speed with Handwheel (mm/min)
It is for limit max speed of each one feeding-axis alone when use handwheel in manual.
Attention:it is valid when >100,otherwise invalid.And suggest don’t over 4000.
30,Type of Acceleration/Deceleration [0 mean line,8 mean curve]
It sets type of accelerate/deceleration.set 0 means line type.set 8 means curve type.
Attention:In normal condition,set line type in servo system;set curve type in step system.
31,Initial Acceleration/Deceleration Constant when curve [>=10]
It is initial accelerate/deceleration constant when P27 set curve type.Range: >=10.
32,Quadratic Acceleration/Deceleration Constant when curve [>=10]
It is quadratic constant of acceleration/deceleration when P27 set curve type. Range >=10.
33,Max Acceleration/Deceleration Constant when curve [>=500]
It is Max acceleration/deceleration constant when P27 set curve type.
It is valid when >=500,otherwise the ace/dec-eleration constant is with line type of each axis.
34,X_Homing Speed (mm/min)
It is homing speed of X-axis.Unit:mm/min. the range is less than X_G00 speed.
35,X_Speed for detect Z0 signal (mm/min)
It is speed for off of homing switch and check Z0 pulse signal after X-axis reach at homing
switch. Unit:mm/min. the range is 20-500.
note:it is for ensure accuracy.the smaller it is ,the higher the accuracy is.when set well,don’t change it forever.
36,Y_Homing Speed (mm/min)
It is homing speed of X-axis.Unit:mm/min. the range is less than Y_G00 speed.
37,Y_Speed for detect Z0 signal (mm/min)
It is speed for off of homing switch and check Z0 pulse signal after Y-axis reach at homing
switch. Unit:mm/min. the range is 20-500.
note:it is for ensure accuracy.the smaller it is ,the higher the accuracy is.when set well,don’t change it forever.