Appendix C. Upgrading Controller Software
EK–SMRAB–IG. B01
C–15
Controller:
HSZ20 CX54300265 Software V31Z, Hardware A02
Not configured for dual-redundancy
SCSI address 7
Time: NOT SET
Host Port:
SCSI target(s) (0, 1, 2, 3), Preferred target(s) (0, 1,
2, 3)
TRANSFER_RATE_REQUESTED = 10MB
Cache:
16 megabyte write cache, version 2
Cache is GOOD
Battery is GOOD
No unflushed data in cache
CACHE_FLUSHED_TIMER = DEFAULT (10 seconds)
CACHE_POLICY = A
Host Functionality Mode = A.
C.6
Reverting to Software Image Version 2.7
To request release V2.7, substitute V27Z.IMG for V31Z.IMG in the previous section as
the correct software image filename. V27Z.IMG is stored in directory (firmware\V27).
C.7
Manual RAID Array 310 Configuration Restoration
The configuration of the storage sets on the RAID array 310 is usually unaffected by
changing the software version. The configuration parameters, however, should be logged
before performing any upgrade.