Getting Started – RAID Array 310 V3.1 for HP–UX
3–2
EK–SMRAB–IG. B01
3.2
Installing the Host Device Driver
The procedures for installing HP-UX device driver(s) require you to be familiar with
following Hewlett-Packard technical manuals:
•
Installing Peripherals
•
System Administrator Tasks
•
How HP-UX Works: Concepts for the System Administrator
Installing the disk driver on HP-UX requires the following major steps:
•
Determine the interface required (Section 3.2.1)
•
Verify the availability of the required device driver (Section 3.2.2)
•
Reboot the system and verify the successful installation (Section 3.2.5)
3.2.1 Determine the Device Driver Required
The device drivers you will need for the StorageWorks RAID Array Controller are listed
in Table 3–1. This driver is software configurable and is a standard part of the HP-UX
operating system. Device files are automatically created for each RAID Array 310 device
when you follow the procedures listed in this section.
If you use SAM, you will not need more detailed information than given in the following
table. However, if you intend to customize your system's configuration, you will need to
refer to "Setting Up Devices Using HP-UX Commands" in the Installing Peripherals
manual. If you need more information on minor numbers, see "Device Files and Minor
Numbers" in the Installing Peripherals manual.
Table 3–1 HP 9000 Drivers
HP FWD SCSI Adapters
Drivers
28696A
disc3, scsi3
built-in, A4107A, or A2969A
sdisk, c720
Содержание EK-SMRAB-IG
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 16: ......
Страница 22: ...Getting Started RAID Array 310 V3 1 for HP UX 1 6 EK SMRAB IG B01 Figure 1 4 Subsystem AC Power Receptacles...
Страница 50: ......
Страница 54: ...Getting Started RAID Array 310 V3 1 for HP UX A 2 EK SMRAB IG B01 Date_____________ LUN Uses...
Страница 56: ......
Страница 72: ......
Страница 84: ......