Getting Started – RAID Array 310 V3.1 for HP-UX
iv
EK–SMRAB-IG. B01
4
Installing Command Console Agent on Your Host System
4.1
Introduction ......................................................................................................... 4–1
4.2
Minimum System Requirements .......................................................................... 4–1
4.3
Installing and Configuring CC Agent for HP-UX
®
............................................... 4–2
4.4
Installing and Configuring Automatically............................................................. 4–2
4.5
Running CC Agent ............................................................................................ 4–10
4.6
Reconfiguring CC Agent.................................................................................... 4–10
4.7
Uninstalling CC Agent....................................................................................... 4–10
4.8
What To Do Next............................................................................................... 4–10
5
Installing the Command Console Client
5.1
Introduction
........................................................................................................ 5–1
5.2
Installing the Client Program
............................................................................ 5–1
5.3
Uninstalling Command Console
....................................................................... 5–2
Appendix A Configuration Records – Blank Forms
Appendix B
Configuration Guidelines
Appendix C Upgrading Your Controller Software
C.1
Backing Up Your System.....................................................................................C–1
C.2
Saving the RAID Array 310 Configuration ..........................................................C–1
C.2.1
Record Logical Units ........................................................................................C–2
C.3
Upgrading Controller Software Using Windows NT ............................................C–5
C.4
Windows NT 3.51 Procedures..............................................................................C–5
C.4.1
Downloading the Software................................................................................C–7
C.5
Firmware Upgrade Procedures for Windows 95 and Windows NT 4.0 ...............C–10
C.5.1
Downloading the Software..............................................................................C–11
C.6
Reverting to Software Image Version 2.7 ...........................................................C–15
C.7
Manual RAID Array 310 Configuration Restoration ..........................................C–15
Appendix D Configuring STRIPEsets, MIRRORsets, and Striped MIRRORsets
D.1
Create a STRIPEset (Configuration Example 1) ...................................................D–1
D.1.1
Initialize the STRIPEset....................................................................................D–1
D.1.2
Add the STRIPEset as a Logical Unit ...............................................................D–2
D.1.3
Set Writeback Cache.........................................................................................D–2
D.2
Create a MIRRORset (Configuration Example 1).................................................D–2
D.2.1
Initialize the MIRRORset .................................................................................D–2
D.2.2
Add the MIRRORset as a Logical Unit .............................................................D–3
D.2.3
Set Writeback Cache.........................................................................................D–3
D.3
Create a Striped MIRRORset (Configuration Example 2).....................................D–3
D.3.1
Create the MIRRORsets ...................................................................................D–3
D.3.2
Create a STRIPEset from the MIRRORsets ......................................................D–3
D.3.3
Initialize the Striped MIRRORset .....................................................................D–4
D.3.4
Add the Striped MIRRORset as a Logical Unit.................................................D–4
D.3.5
Set Writeback Cache.........................................................................................D–4
D.4
Add Individual Disks as Logical Units (Configuration Example 2) ......................D–5
D.5
Add Drives to the Spareset ...................................................................................D–5
Содержание EK-SMRAB-IG
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 16: ......
Страница 22: ...Getting Started RAID Array 310 V3 1 for HP UX 1 6 EK SMRAB IG B01 Figure 1 4 Subsystem AC Power Receptacles...
Страница 50: ......
Страница 54: ...Getting Started RAID Array 310 V3 1 for HP UX A 2 EK SMRAB IG B01 Date_____________ LUN Uses...
Страница 56: ......
Страница 72: ......
Страница 84: ......