Appendix C. Upgrading Controller Software
EK–SMRAB–IG. B01
C–13
7. Type: 2 and press the Return key. The utility displays the following message:
Perform the following steps before continuing:
•
get new image file on the serial line host computer
•
* configure KERMIT with the following parameters:
•
terminal speed 19200 baud, eight bit, no parity,
•
1 stop bit
It will take approximately 35 to 45 minutes to perform the code load
operation.
WARNING: proceeding with Code Load will overwrite the current
content of your program code with a new image. Enter Y (then RETURN)
to continue
[N] ? y
Start KERMIT now…
8. Select Send File from the Transfer menu.
Figure C–3 Select Send File from the Transfer Menu
9. Type the location of the firmware image file (V31Z.IMG) in the Filename box.
Select Kermit in the Protocol box and click the Send button.