44
14 January 2021, SmartScanIS User’s Guide for Union Pacific, EUD-2016026-00 Rev.2
4.3.2 Pinout
The J1 connector provides connections for module power and presence signal output. The
table below shows the J1 pinout.
Pin #
Function
1
BATT+ (9 VDC to 28 VDC)
2
GND
3
PRES OUT
4
NC
The J2 terminal block is for the track circuit inputs. One rail is connected to terminal-1, the
opposite rail to terminal-2. Polarity makes no difference.
4.3.3 2300-528 Zepic III Board
The Zepic III board (aka SOTC board) operates on a voltage range of 9 to 24 VDC. This
board provides a consistent activation point independent of input voltage. The semiautomated
track circuit setup feature makes calibration quick and easy. Just place a shunt and push a
button.
Calibration Switch