14 January 2021, SmartScanIS User’s Guide for Union Pacific, EUD-2016026-00 Rev.2
11.3.4 Alarm Limits
To set or change one or more of the alarm limits:
1
Be sure that the Setup menu is displayed.
The top part of the Setup menu looks like this.
STC Integrated Detector System, Milepost-0501.2, Track:Single
05/31/2013
9:35
Setup Menu
------------------------------------------------
A) Set Date and Time
B) Milepost
C) Track Number
D) Alarm Limits
E) Equipment
•
•
•
2
Select
Alarm Limits
.
A menu and prompt like this appears.
Milepost-0501.2, Track:Single
Alarm Limits
---------------------------------------------------
A) Absolute................... 180°
B) Differential...............
90°
C) Hot Wheel.................. 540°
D) Cold Wheel.................
30°
E) CS Slope................... 0.32
F) CS Minimum.................
37°
G) Cold Journal...............
10°
H) Cold Wheel Scanner.........
30°
I) Cold Trains.................
3
J) Sliding Wheel Ratio......... 50%
K) Max Alarms..................
6
Alarm to change or Esc to quit?
This menu option allows you to change the various alarm limits that affect system
operations. The current setting for each limit is displayed. To change one of the alarm
limit settings, start by typing the letter corresponding to the desired option.
Содержание SmartScanIS
Страница 1: ...EUD 2016026 00 Rev 2 SmartScanIS User s Guide for Union Pacific 14 January 2021...
Страница 82: ...82 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 90: ...90 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 130: ...130 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 258: ...258 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 376: ...376 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...
Страница 380: ...380 14 January 2021 SmartScanIS User s Guide for Union Pacific EUD 2016026 00 Rev 2...